Real-time monitoring of powder mixing in a convective blender using non-invasive reflectance NIR spectrometry

被引:44
作者
Bellamy, Luke J. [1 ,2 ]
Nordon, Alison [1 ,2 ]
Littlejohn, David [1 ,2 ]
机构
[1] Univ Strathclyde, Dept Pure & Appl Chem, WestCHEM, Glasgow G1 1XL, Lanark, Scotland
[2] Univ Strathclyde, CPAT, Glasgow G1 1XL, Lanark, Scotland
关键词
D O I
10.1039/b713919e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A convective blender based on a scaled down version of a high shear mixer-granulator was used to produce binary mixtures of microcrystalline cellulose (Avicel) and aspirin, citric acid, aspartame or povidone. Spectra of stationary Avicel or aspirin powder provided an indication of the information depth achieved with the NIR spectrometer used in the study, and confirmed previously reported effects of particle size and wavenumber. However, it was demonstrated that for 10% w/w aspirin in Avicel, the information depth at the C-H second overtone of aspirin (about 2.4 mm) was unaffected by changes in the particle size of aspirin and was determined by the major component. By making non-invasive NIR measurements as powders were mixed, it was possible to illustrate differences in the mixing characteristics of aspirin, citric acid, aspartame or povidone with Avicel, which were related to differences in the cohesive properties of the particles. Mixing profiles based on second overtone signals were better for quantitative analysis than those derived from first overtone measurements. It was also demonstrated that the peak-to-peak noise of the mixing profile obtained from the second overtone of aspirin changed linearly with the particle size of aspirin added to Avicel. Hence, measurement of the mixing profile in real time with NIR spectrometry provided simultaneously the opportunity to study the dynamics of powder mixing, make quantitative measurements and monitor possible changes in particle size during blending.
引用
收藏
页码:58 / 64
页数:7
相关论文
共 35 条
[1]   NIR spectroscopy on moving solids using a scanning grating spectrometer - impact on multivariate process analysis [J].
Andersson, M ;
Svensson, O ;
Folestad, S ;
Josefson, M ;
Wahlund, KG .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2005, 75 (01) :1-11
[2]   Characterizing mixing and lubrication in the Bohle Bin blender [J].
Arratia, PE ;
Duong, NH ;
Muzzio, FJ ;
Godbole, P ;
Lange, A ;
Reynolds, S .
POWDER TECHNOLOGY, 2006, 161 (03) :202-208
[3]  
Bellamy L., 2004, SPECTROSC EUR, V16, P30
[4]  
BELLAMY LJ, 2004, THESIS U STRATHCLYDE
[5]   Quantitative in-line monitoring of powder blending by near infrared reflection spectroscopy [J].
Berntsson, O ;
Danielsson, LG ;
Lagerholm, B ;
Folestad, S .
POWDER TECHNOLOGY, 2002, 123 (2-3) :185-193
[6]   Characterization of diffuse reflectance fiber probe sampling on moving solids using a Fourier transform near-infrared spectrometer [J].
Berntsson, O ;
Danielsson, LG ;
Folestad, S .
ANALYTICA CHIMICA ACTA, 2001, 431 (01) :125-131
[7]   Quantitative determination of content in binary powder mixtures using diffuse reflectance near infrared spectrometry and multivariate analysis [J].
Berntsson, O ;
Danielsson, LG ;
Johansson, MO ;
Folestad, S .
ANALYTICA CHIMICA ACTA, 2000, 419 (01) :45-54
[8]   Effective sample size in diffuse reflectance near-IR spectrometry [J].
Berntsson, O ;
Burger, T ;
Folestad, S ;
Danielsson, LG ;
Kuhn, J ;
Fricke, J .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :617-623
[9]   Estimation of effective sample size when analysing powders with diffuse reflectance near-infrared spectrometry [J].
Berntsson, O ;
Danielsson, LG ;
Folestad, S .
ANALYTICA CHIMICA ACTA, 1998, 364 (1-3) :243-251
[10]   Monitoring powder blending in pharmaceutical processes by use of near infrared spectroscopy [J].
Blanco, M ;
Bañó, RG ;
Bertran, E .
TALANTA, 2002, 56 (01) :203-212