Quantitative assessment of inter-clinician variability of target volume delineation for medulloblastorna: quality assurance for the SIOP PNET 4 trial protocol

被引:43
作者
Coles, CE
Hoole, ACF
Harden, SV
Burnet, NG
Twyman, N
Taylor, RE
Kortmann, RD
Williams, MV
机构
[1] Addenbrookes Hosp, Ctr Oncol, Cambridge CB2 2QQ, England
[2] Univ Cambridge, Addenbrookes Hosp, Dept Oncol, Cambridge CB2 2QQ, England
[3] Cookridge Hosp, Leeds LS16 6QB, W Yorkshire, England
[4] Univ Tuebingen, Tubingen, Germany
关键词
conformal planning; medulloblastoma; quality assurance;
D O I
10.1016/j.radonc.2003.09.009
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: To assess inter-clinician variability amongst specialist paediatric radiation oncologists in delineating clinical target volumes for treating medulloblastoma as a quality assurance exercise prior to the introduction of the SIOP PNET 4 trial protocol of conformal radiotherapy to the posterior fossa and tumour bed. Patients and methods: Participants from 17 UK centres attended an educational meeting and then completed a clinical planning exercise to outline: (1) the whole posterior fossa and (2) the tumour bed. Quantitative analysis of the volumes, lengths, spatial positioning and axial planes for each individual was carried out and variation between individuals analysed. Results: Outlining of the posterior fossa was reasonably consistent, although most variation was seen in defining the superior border of the tentorium. A major difference was the decision whether or not to include the post-surgical meningocoele in the clinical target volume (CTV). The CTV for the tumour bed was under treated by all participants due to lack of inclusion of pre-operative tumour extent. Conclusions: This exercise demonstrated several ambiguities in the draft protocol and highlighted particular areas of inter-clinician variation. Consequently the protocol was revised and improved to take account of these findings. We recommend that planning exercises, in conjunction with education and training, should be implemented before the start of any new radiotherapy trial. In the future, the use of image transfer will allow prospective peer review of target volumes before treatment commences. These measures are essential to ensure that alterations in clinical practice are achieved in a uniform way. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:189 / 194
页数:6
相关论文
共 15 条
[1]   Impact of targeting deviations on outcome in medulloblastoma: Study of the French Society of Pediatric Oncology (SFOP) [J].
Carrie, C ;
Hoffstetter, S ;
Gomez, F ;
Moncho, V ;
Doz, F ;
Alapetite, C ;
Murraciole, X ;
Maire, JP ;
Benhassel, M ;
Chapet, S ;
Quetin, P ;
Kolodie, H ;
Lagrange, JL ;
Cuillere, JC ;
Habrand, JL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02) :435-439
[2]   Interphysician variability in defining the planning target volume in the irradiation of prostate and seminal vesicles [J].
Cazzaniga, LF ;
Marinoni, MA ;
Bossi, A ;
Bianchi, E ;
Cagna, E ;
Cosentino, D ;
Scandolaro, L ;
Valli, M ;
Frigerio, M .
RADIOTHERAPY AND ONCOLOGY, 1998, 47 (03) :293-296
[3]   Rectum contouring variability in patients treated for prostate cancer: impact on rectum dose-volume histograms and normal tissue complication probability [J].
Fiorino, C ;
Vavassori, V ;
Sanguineti, G ;
Bianchi, C ;
Cattaneo, GM ;
Piazzolla, A ;
Cozzarini, C .
RADIOTHERAPY AND ONCOLOGY, 2002, 63 (03) :249-255
[4]   Intra- and inter-observer variability in contouring prostate and seminal vesicles: implications for conformal treatment planning [J].
Fiorino, C ;
Reni, M ;
Bolognesi, A ;
Cattaneo, GM ;
Calandrino, R .
RADIOTHERAPY AND ONCOLOGY, 1998, 47 (03) :285-292
[5]   Variability in target volume delineation on CT scans of the breast [J].
Hurkmans, CW ;
Borger, JH ;
Pieters, BR ;
Russell, NS ;
Jansen, EPM ;
Mijnheer, BJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (05) :1366-1372
[6]   Consistency of three-dimensional planning target volumes across physicians and institutions [J].
Ketting, CH ;
AustinSeymour, M ;
Kalet, I ;
Unger, J ;
Hummel, S ;
Jacky, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (02) :445-453
[7]   QUALITY ASSESSMENT OF MEDICAL DECISION-MAKING IN RADIATION ONCOLOGY - VARIABILITY IN TARGET VOLUME DELINEATION FOR BRAIN-TUMORS [J].
LEUNENS, G ;
MENTEN, J ;
WELTENS, C ;
VERSTRAETE, J ;
VANDERSCHUEREN, E .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :169-175
[8]  
Muracciole X., 2002, International Journal of Radiation Oncology Biology Physics, V54, P148, DOI 10.1016/S0360-3016(02)03315-1
[9]  
Pitkänen MA, 2001, ACTA ONCOL, V40, P50
[10]   Target volume definition in conformal radiotherapy for prostate cancer: quality assurance in the MRC RT-01 trial [J].
Seddon, B ;
Bidmead, M ;
Wilson, J ;
Khoo, V ;
Dearnaley, D .
RADIOTHERAPY AND ONCOLOGY, 2000, 56 (01) :73-83