Background and purpose: Prior to randomization of patients into the UK Medical Research Council multicentre randomized trial (RT-01) of conformal radiotherapy (CFRT) in prostate cancer, clinicians at participating centres were required to complete a quality assurance (QA) clinical planning exercise to enable an investigation of inter-observer variability in gross target volume (GTV) and normal structure outlining. Materials and methods: Thirteen participating centres and two investigators completed the clinical planning exercise of three practice planning cases. Clinicians were asked to draw outlines of the GTV, rectum and bladder on hard-copy computerized tomography (CT) films of the pelvis, which were transferred onto the Cadplan computer planning system by a single investigator. Centre, inferior and superior CT levels of GTV, rectum and bladder were noted, and volume calculations performed. Planning target volumes (PTV) were generated using automatic volume expansion of GTVs by a 1 cm margin. Anterior, right and left lateral beam eye views (BEV) of the PTVs were generated. Using a common central point, the BEV PTVs were superimposed for each beam direction of each case. Radial PTV variation was investigated by measurement of a novel parameter, termed the radial line measurement variation (RLMV). Results: GTV central slice and length were defined with reasonable consistency. The RLMV analysis showed that the main part of the prostate gland, bladder and inferior rectum were outlined with good consistency among clinicians. However, the outlining of the prostatic apex, superior aspect of the prostate projecting into the bladder, seminal vesicles, the base of seminal vesicles and superior rectum were more variable. Conclusion: This exercise has demonstrated adequate consistency of GTV definition. The RLMV method of analysis indicates particular regions of clinician uncertainty. Appropriate feedback has been given to all participating clinicians, and the final RT-01 trial protocol has been modified to accommodate these findings. (C) 2000 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:73 / 83
页数:11
相关论文
共 21 条
[1]   Comparability of CT-based and TRUS-based prostate volumes [J].
Badiozamani, KR ;
Wallner, K ;
Cavanagh, W ;
Blasko, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (02) :375-378
[2]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[3]   High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging [J].
Bel, A ;
Vos, PH ;
Rodrigus, PTR ;
Creutzberg, CL ;
Visser, AG ;
Stroom, JC ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :321-332
[4]   MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER [J].
BIJHOLD, J ;
LEBESQUE, JV ;
HART, AAM ;
VIJLBRIEF, RE .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) :261-271
[5]   Interphysician variability in defining the planning target volume in the irradiation of prostate and seminal vesicles [J].
Cazzaniga, LF ;
Marinoni, MA ;
Bossi, A ;
Bianchi, E ;
Cagna, E ;
Cosentino, D ;
Scandolaro, L ;
Valli, M ;
Frigerio, M .
RADIOTHERAPY AND ONCOLOGY, 1998, 47 (03) :293-296
[6]   AN ALGORITHM FOR VOLUME ESTIMATION BASED ON POLYHEDRAL APPROXIMATION [J].
COOK, LT ;
COOK, PN ;
LEE, KR ;
BATNITZKY, S ;
WONG, BYS ;
FRITZ, SL ;
OPHIR, J ;
DWYER, SJ ;
BIGONGIARI, LR ;
TEMPLETON, AW .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (09) :493-500
[7]  
DEARNALEY DP, 1994, INT CONGR SER, V1064, P197
[8]   OBJECTIVE DECISION-MAKING FOLLOWING A PORTAL FILM - THE RESULTS OF A PILOT-STUDY [J].
DENHAM, JW ;
DALLY, MJ ;
HUNTER, K ;
WHEAT, J ;
FAHEY, PP ;
HAMILTON, CS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (05) :869-876
[9]   Intra- and inter-observer variability in contouring prostate and seminal vesicles: implications for conformal treatment planning [J].
Fiorino, C ;
Reni, M ;
Bolognesi, A ;
Cattaneo, GM ;
Calandrino, R .
RADIOTHERAPY AND ONCOLOGY, 1998, 47 (03) :285-292
[10]   Accuracy of pelvic radiotherapy: Prospective analysis of 90 patients in a randomised trial of blocked versus standard radiotherapy [J].
Huddart, RA ;
Nahum, A ;
Neal, A ;
McLean, M ;
Dearnaley, DP ;
Law, M ;
Dyer, J ;
Tait, D .
RADIOTHERAPY AND ONCOLOGY, 1996, 39 (01) :19-29