Microfluidic sedimentation cytometer for milk quality and bovine mastitis monitoring

被引:34
作者
Garcia-Cordero, Jose L. [1 ]
Barrett, Louise M. [1 ]
O'Kennedy, Richard [1 ]
Ricco, Antonio J. [1 ]
机构
[1] Dublin City Univ, Biomed Diagnost Inst, Natl Ctr Sensor Res, Dublin 9, Ireland
基金
爱尔兰科学基金会;
关键词
Bovine mastitis; Milk; Cytometer; Centrifugal microfluidics; Sedimentation; Cell-counter; Somatic cells; Sample-to-answer device; SOMATIC-CELL COUNTS; PARTICLES; HEALTH; DEVICE; FAT;
D O I
10.1007/s10544-010-9459-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We report a rapid, low-cost, portable microfluidic sedimentation cytometer (SeCy) for assessing the somatic cell count and fat content of milk in 15 min using a "sample-in, answer-out" approach. The system consists of 12 independent microfluidic devices, essentially flattened funnel structures, fabricated on the footprint of a single plastic compact disc (CD). Each funnel structure holds 150 mu L of milk, has an inlet for milk filling and an outlet for air to escape, and ends in a narrow, closed-end microfluidic channel that facilitates packing of the cells into a column whose length is proportional to cell count. The closed-end channel provides accurate cell counts over the range 50,000-> 3,000,000 cells per mL. The assay separates cells and fat globules based on their densities (by differential sedimentation), concentrating white cells in the closed-end channel near the outer rim of the CD for estimation of total "cell pellet" volume, while fat globules move toward the center of disc rotation, forming a fat "band" in the funnel. After adding milk to two or more microfluidic devices, the CD is loaded onto a custom-built reader unit that spins the disc for 15 min. Two low-cost microscopes in the reader image the centrifuged cell pellet and the fat band, providing a sufficiently accurate cell count to diagnose mastitis and measuring fat content as an indication of health and nutritional status.
引用
收藏
页码:1051 / 1059
页数:9
相关论文
共 33 条
[1]  
[Anonymous], 1999, DAIRY TECHNOLOGY PRI
[2]   Potential to alter the content and composition of milk fat through nutrition [J].
Ashes, JR ;
Gulati, SK ;
Scott, TW .
JOURNAL OF DAIRY SCIENCE, 1997, 80 (09) :2204-2212
[3]   The good, the bad, and the tiny: a review of microflow cytometry [J].
Ateya, Daniel A. ;
Erickson, Jeffrey S. ;
Howell, Peter B., Jr. ;
Hilliard, Lisa R. ;
Golden, Joel P. ;
Ligler, Frances S. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (05) :1485-1498
[4]  
BERRY E, 2003, P BRIT MAST C
[5]   A microfluidic device for practical label-free CD4+T cell counting of HIV-infected subjects [J].
Cheng, Xuanhong ;
Irimia, Daniel ;
Dixon, Meredith ;
Sekine, Kazuhiko ;
Demirci, Utkan ;
Zamir, Lee ;
Tompkins, Ronald G. ;
Rodriguez, William ;
Toner, Mehmet .
LAB ON A CHIP, 2007, 7 (02) :170-178
[6]   Cell detection and counting through cell lysate impedance spectroscopy in microfluidic devices [J].
Cheng, Xuanhong ;
Liu, Yi-shao ;
Irimia, Daniel ;
Demirci, Utkan ;
Yang, Liju ;
Zamir, Lee ;
Rodriguez, William R. ;
Toner, Mehmet ;
Bashir, Rashid .
LAB ON A CHIP, 2007, 7 (06) :746-755
[7]   Enhancing the performance of a point-of-care CD4+T-cell counting microchip through monocyte depletion for HIV/AIDS diagnostics [J].
Cheng, Xuanhong ;
Gupta, Amit ;
Chen, Chihchen ;
Tompkins, Ronald G. ;
Rodriguez, William ;
Toner, Mehmet .
LAB ON A CHIP, 2009, 9 (10) :1357-1364
[8]   Recent advances in miniaturized microfluidic flow cytometry for clinical use [J].
Chung, Taek Dong ;
Kim, Hee Chan .
ELECTROPHORESIS, 2007, 28 (24) :4511-4520
[9]   Deterministic hydrodynamics: Taking blood apart [J].
Davis, John A. ;
Inglis, David W. ;
Morton, Keith J. ;
Lawrence, David A. ;
Huang, Lotien R. ;
Chou, Stephen Y. ;
Sturm, James C. ;
Austin, Robert H. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (40) :14779-14784
[10]   Improving the density of jammed disordered packings using ellipsoids [J].
Donev, A ;
Cisse, I ;
Sachs, D ;
Variano, E ;
Stillinger, FH ;
Connelly, R ;
Torquato, S ;
Chaikin, PM .
SCIENCE, 2004, 303 (5660) :990-993