Elimination of microcystins by water treatment processes - examples from Sulejow Reservoir, Poland

被引:89
作者
Jurczak, T
Tarczynska, M
Izydorczyk, K
Mankiewicz, J
Zalewski, M
Meriluoto, J
机构
[1] Univ Lodz, Dept Appl Ecol, PL-90237 Lodz, Poland
[2] Polish Acad Sci, Int Ctr Ecol, PL-90950 Lodz, Poland
[3] Abo Akad Univ, Dept Biochem & Pharm, Turku 20520, Finland
关键词
microcystins; cyanobacteria; drinking water; water treatment process; removal;
D O I
10.1016/j.watres.2005.04.031
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Eutrophication is a serious problem in Polish freshwaters. Mass occurrences of toxic cyanobacteria in reservoirs cause problems in the production of safe drinking water and the diversity of produced toxins complicates monitoring of freshwaters. The aim of this study was to estimate the efficiency of water treatment processes in the removal of microcystins (MCs), cyanobacterial hepatotoxins. Elimination of microcystins was studied at two waterworks, which supply drinking water to the city of Lodz from Sulejow Reservoir. The consecutive steps of pre-oxidation, coagulation, sand filtration, ozonation and chlorination used in the water treatment showed effective elimination of microcystins in water from Sulejow Reservoir in 2002 and 2003. The highest total concentration of microcystin (variants MC-RR, MC-YR, MC-LR) amounted to 6.7 mu g l(-1) in raw water and was detected on the 13th of August 2002. In 2003 the water utility decided to increase the contribution of ground water in the production of drinking water. This resulted in a decrease of microcystin in water during and after the treatment process. The current management strategy of the waterworks company includes mixing of surface water and ground water, which reduces the hazards caused by toxic cyanobacterial blooms in the reservoir. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2394 / 2406
页数:13
相关论文
共 42 条
[11]  
Fawell J. K., 1991, DETECTION REMOVAL CY
[12]  
Hart J., 1993, MICROCYSTIN LR REMOV
[13]  
HART J, 1997, IWSA WORLD C
[14]   THE EFFECT OF WATER-TREATMENT PROCESSES ON THE REMOVAL OF HEPATOTOXINS FROM MICROCYSTIS AND OSCILLATORIA CYANOBACTERIA - A LABORATORY STUDY [J].
HIMBERG, K ;
KEIJOLA, AM ;
HIISVIRTA, L ;
PYYSALO, H ;
SIVONEN, K .
WATER RESEARCH, 1989, 23 (08) :979-984
[15]   Cyanobacterial toxins:: Removal during drinking water treatment, and human risk assessment [J].
Hitzfeld, BC ;
Höger, SJ ;
Dietrich, DR .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2000, 108 :113-122
[16]   Occurrence and elimination of cyanobacterial toxins in two Australian drinking water treatment plants [J].
Hoeger, SJ ;
Shaw, G ;
Hitzfeld, BC ;
Dietrich, DR .
TOXICON, 2004, 43 (06) :639-649
[17]  
HOFFMANN J R H, 1976, Water S A (Pretoria), V2, P58
[18]  
HOUSE J, 2004, MANAGEMENT STRATEGIE
[19]   Characterization and diversity of cyanobacterial hepatotoxins (microcystins) in blooms from polish freshwaters identified by liquid chromatography-electrospray ionisation mass spectrometry [J].
Jurczak, T ;
Tarczyñska, M ;
Karlsson, K ;
Meriluoto, J .
CHROMATOGRAPHIA, 2004, 59 (9-10) :571-578
[20]   REMOVAL OF CYANOBACTERIAL TOXINS IN WATER-TREATMENT PROCESSES - LABORATORY AND PILOT-SCALE EXPERIMENTS [J].
KEIJOLA, AM ;
HIMBERG, K ;
ESALA, AL ;
SIVONEN, K ;
HIISVIRTA, L .
TOXICITY ASSESSMENT, 1988, 3 (05) :643-656