A membrane-based displacement flow immunoassay

被引:26
作者
Rabbany, SY
Marganski, WA
Kusterbeck, AW
Ligler, FS
机构
[1] Hofstra Univ, Bioengn Program, Hempstead, NY 11549 USA
[2] USN, Res Lab, Ctr Biomol Sci & Engn, Washington, DC 20375 USA
关键词
explosives detection; displacement immunoassay; membrane; biosensor; immobilized IgG;
D O I
10.1016/S0956-5663(98)00031-1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The use of a membrane-based continuous Bow displacement immunoassay for detection of nanomolar quantities of explosives is demonstrated, and the kinetics of this system are characterized through experimentation. Antibodies of 2,4,6-trinitrotoluene (TNT) are immobilized onto a porous membrane with surface reactive sites designed to facilitate the covalent binding of the antibody. After saturating the immobilized antibody binding sites with labeled antigen, target analyte is introduced in Bow, and the displacement reactions are monitored using a fluorometer. The displaced labeled antigen detected is proportional to the concentration of the analyte introduced to the antibody-labeled antigen complex. Multiple assays were performed at Bow rates of 2.0, 1.0, 0.50, and 0.25 mL/min using membranes saturated with varying TNT antibody concentrations. The signal intensity (i.e. the concentration of displaced labeled antigen) was independent of antibody concentration at 1.0 mL/min, but proportional to antibody concentration at 0.25 mL/min. Our data suggests that the lower flow rate created a longer interaction time between the injected analyte and the antibody-labeled antigen complex, resulting in greater displacement of the labeled antigen and higher signal intensities than seen at higher flow rates. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:939 / 944
页数:6
相关论文
共 19 条
[11]  
Rabbany Sina Y., 1994, Critical Reviews in Biomedical Engineering, V22, P307
[12]   EFFECT OF ANTIBODY DENSITY ON THE DISPLACEMENT KINETICS OF A FLOW IMMUNOASSAY [J].
RABBANY, SY ;
KUSTERBECK, AW ;
BREDEHORST, R ;
LIGLER, FS .
JOURNAL OF IMMUNOLOGICAL METHODS, 1994, 168 (02) :227-234
[13]   Assessment of heterogeneity in antibody-antigen displacement reactions [J].
Rabbany, SY ;
Piervincenzi, R ;
Judd, L ;
Kusterbeck, AW ;
Bredehorst, R ;
Hakansson, K ;
Ligler, FS .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :175-182
[14]   BINDING-KINETICS OF IMMOBILIZED ANTIBODIES IN A FLOW IMMUNOSENSOR [J].
RABBANY, SY ;
KUSTERBECK, AW ;
BREDEHORST, R ;
LIGLER, FS .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 29 (1-3) :72-78
[15]  
RABBANY SY, 1996, P IEEE ENG MED BIOL
[16]   DETECTION OF TNT IN WATER USING AN EVANESCENT-WAVE FIBEROPTIC BIOSENSOR [J].
SHRIVERLAKE, LC ;
BRESLIN, KA ;
CHARLES, PT ;
CONRAD, DW ;
GOLDEN, JP ;
LIGLER, FS .
ANALYTICAL CHEMISTRY, 1995, 67 (14) :2431-2435
[17]   IMMUNOCHEMICAL METHODS - FOR ENVIRONMENTAL-ANALYSIS [J].
VANEMON, JM ;
LOPEZAVILA, V .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :A79-A88
[18]   KINETICS OF ANTIBODY-BINDING AT SOLID-LIQUID INTERFACES IN FLOW [J].
WEMHOFF, GA ;
RABBANY, SY ;
KUSTERBECK, AW ;
OGERT, RA ;
BREDEHORST, R ;
LIGLER, FS .
JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 156 (02) :223-230
[19]   CONTINUOUS-FLOW IMMUNOSENSOR FOR DETECTION OF EXPLOSIVES [J].