Correlation of pre-operative MRI and intra-operative 3D ultrasound to measure brain tissue shift

被引:6
作者
Gobbi, DG [1 ]
Lee, BKH [1 ]
Peters, TM [1 ]
机构
[1] John P Robarts Res Inst, London, ON N6A 4K8, Canada
来源
MEDICAL IMAGING 2001: VISUALIZATION, DISPLAY, AND IMAGE-GUIDED PROCEDURES | 2001年 / 4319卷
关键词
3D ultrasound; brain shift; intraoperative ultrasound; image guided surgery; neurosurgery;
D O I
10.1117/12.428064
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
B-Mode ultrasound is often used during neurosurgery to provide intra-operative images of the brain through a craniotomy, but the use of 3D ultrasound during surgery is still in its infancy. We have developed a system that provides real-time freehand 3D ultrasound reconstruction at a reduced resolution. The reconstruction proceeds incrementally and the 3D image is overlayed, via a computer, on a pre-operative 3D MRI scan. This provides the operator with the necessary feedback to maintain a constant freehand sweep-rate, and also ensures that the sweep covers the desired anatomical volume. All of the ultrasound video frames are buffered, and a full-resolution, compounded reconstruction proceeds once the manual sweep is complete. We have also developed tools for manual tagging of homologous landmarks in the 3D MRI and 3D ultrasound volumes that use a piecewise cubic approximation of thin-plate spline interpolation to achieve interactive nonlinear registration and warping of the MRI volume to the ultrasound volume: Each time a homologous point-pair is identified by the user, the image of the warped MRI is updated on the computer screen after less than 0.5 s.
引用
收藏
页码:264 / 271
页数:8
相关论文
共 17 条
[1]  
BOOKSTEIN FL, 1999, BRAIN WARPING
[2]  
Bucholz RD, 1997, LECT NOTES COMPUT SC, V1205, P459, DOI 10.1007/BFb0029268
[3]   Polyvinyl alcohol cryogel: An ideal phantom material for MR studies of arterial flow and elasticity [J].
Chu, KC ;
Rutt, BK .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) :314-319
[4]   Intraoperative ultrasound for guidance and tissue shift correction in image-guided neurosurgery [J].
Comeau, RM ;
Sadikot, AF ;
Fenster, A ;
Peters, TM .
MEDICAL PHYSICS, 2000, 27 (04) :787-800
[5]  
COMEAU RM, SPIE, V3338, P474
[6]   Preliminary clinical experience with intraoperative stereotactic ultrasound imaging [J].
Giorgi, C ;
Casolino, DS .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1997, 68 (1-4) :54-58
[7]  
Gobbi DG, 2000, LECT NOTES COMPUT SC, V1935, P106
[8]  
Gobbi DG, 1999, LECT NOTES COMPUT SC, V1679, P920
[9]   SonoWand, an ultrasound-based neuronavigation system [J].
Gronningsaeter, A ;
Kleven, A ;
Ommedal, S ;
Aarseth, TE ;
Lie, T ;
Lindseth, F ;
Lango, T ;
Unsgard, G .
NEUROSURGERY, 2000, 47 (06) :1373-1379
[10]   Development of a frameless and armless stereotactic neuronavigation system with ultrasonographic registration [J].
Hata, N ;
Dohi, T ;
Iseki, H ;
Takakura, K .
NEUROSURGERY, 1997, 41 (03) :608-613