Contrast-enhanced magnetic resonance imaging of the coronary arteries - A review

被引:27
作者
Li, DB [1 ]
Zheng, J [1 ]
Bae, KTT [1 ]
Woodard, PK [1 ]
Haacke, EM [1 ]
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
magnetic resonance imaging; coronary arteries; contrast agents; fast imaging;
D O I
10.1097/00004424-199809000-00014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The advent and continued improvement of T1-shortening contrast media have revolutionized magnetic resonance angiography (MRA) of the entire body in recent years, The technical basis for contrast-enhanced MRA is fast three-dimensional (3D) imaging, A brief historic review of the technical advances in MR coronary artery imaging clearly points to the importance of improved gradient capabilities that led to the development and wide application of fast 3D imaging. The use of contrast agents in coronary artery imaging has been expected for many years, given its success in other parts of the body. Nevertheless, because of the potential difficulties and unique characteristics of fast 3D imaging in the heart, the utility of contrast agents in coronary artery imaging has been systematically investigated only in the last 2 years. Initial experience from our group and others showed that contrast agents have great potential in pushing MR coronary artery imaging to a much higher level in terms of speed and signal-to-noise ratio (SNR), and intravascular agents are more desirable than extracellular agents. Nevertheless, because of the technical challenges and the diversity of methods used for coronary artery imaging, much more effort is needed to continue to improve the imaging techniques and further to define the roles of contrast agents in coronary artery imaging.
引用
收藏
页码:578 / 586
页数:9
相关论文
共 54 条
[11]   MAGNETIC-RESONANCE-IMAGING THE VELOCITY VECTOR COMPONENTS OF FLUID-FLOW [J].
FEINBERG, DA ;
CROOKS, LE ;
SHELDON, P ;
HOENNINGER, J ;
WATTS, J ;
ARAKAWA, M .
MAGNETIC RESONANCE IN MEDICINE, 1985, 2 (06) :555-566
[12]   Coronary arteries: Breath-hold, gadolinium-enhanced, three-dimensional MR angiography [J].
Goldfarb, JW ;
Edelman, RR .
RADIOLOGY, 1998, 206 (03) :830-834
[13]   CORONARY-ARTERY BYPASS GRAFTS - VISUALIZATION WITH MR IMAGING [J].
GOMES, AS ;
LOIS, JF ;
DRINKWATER, DC ;
CORDAY, SR .
RADIOLOGY, 1987, 162 (01) :175-179
[14]   Steady-state and dynamic MR angiography with MS-325: Initial experience in humans [J].
Grist, TM ;
Korosec, FR ;
Peters, DC ;
Witte, S ;
Walovitch, RC ;
Dolan, RP ;
Bridson, WE ;
Yucel, EK ;
Mistretta, CA .
RADIOLOGY, 1998, 207 (02) :539-544
[15]   IMPROVING MR IMAGE QUALITY IN THE PRESENCE OF MOTION BY USING REPHASING GRADIENTS [J].
HAACKE, EM ;
LENZ, GW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (06) :1251-1258
[16]   Optimization of contrast timing for breath-hold three-dimensional MR angiography [J].
Hany, TF ;
McKinnon, GC ;
Leung, DA ;
Pfammatter, T ;
Debatin, JF .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03) :551-556
[17]   Pulmonary perfusion and angiography: Evaluation with breath-hold enhanced three-dimensional fast imaging steady-state precession MR imaging with short TR and TE [J].
Hatabu, H ;
Gaa, J ;
Kim, D ;
Li, W ;
Prasad, PV ;
Edelman, RR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (03) :653-655
[18]  
HOFMAN MBM, 1995, J COMPUT ASSIST TOMO, V19, P56
[19]  
HOFMAN MBM, 1997, P ISMRM 5 ANN M VANC, P442
[20]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351