Flow-through sorptive preconcentration with direct optosensing at solid surfaces for trace-ion analysis

被引:30
作者
Miró, M
Frenzel, W
机构
[1] Univ Balear Isl, Dept Chem, Fac Sci, E-07122 Palma de Mallorca, Illes Balears, Spain
[2] Tech Univ Berlin, Inst Tech Umweltschutz, D-10623 Berlin, Germany
关键词
flowing stream methods; ionic species; optosensing; sorptive preconcentration;
D O I
10.1016/S0165-9936(04)00107-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article highlights the potential of the solid-phase optosensing scheme as a microanalytical technique for the monitoring of ionic species at the low ng/ml level. We describe the background of solid-phase optosensing, critically comparing the performance of its applications in batch and flowing stream systems. We discuss in detail the current state of the art of flow-through solid-phase extraction (SPE)-based sensors, which are regarded as being a mature technique, and we outline its intrinsic and unique analytical features. We give special emphasis to the criteria to be fulfilled by both bead and membrane sorbent materials if used in a reversible fashion. We also thoroughly address the potentialities and limitations of different optrode cell designs devoted to absorbance/reflectance detection. We present the concept of renewable-bead injection as a powerful scheme that can be exploited with a wide variety of reagent-based assays, including those relying on irreversible reactions. As a practical example to compare the analytical performance of the variety of approaches and cell configurations described in the bulk of the text, we selected on-column monitoring of ultratrace levels of nitrite, which involved the reversed-phase extraction of the derivative compound resulting from the Shinn reaction. (C) 2003 Published by Elsevier B.V.
引用
收藏
页码:11 / 20
页数:10
相关论文
共 48 条
[21]   Determination of ultratraces of nitrite by solid-phase preconcentration using a novel flow-through spectrophotometric optrode [J].
Miró, M ;
Frenzel, W ;
Cerdà, V ;
Estela, JM .
ANALYTICA CHIMICA ACTA, 2001, 437 (01) :55-65
[22]  
MIRO M, UNPUB TALANTA
[23]   OPTICAL CHEMICAL SENSORS - TRANSDUCTION AND SIGNAL-PROCESSING [J].
NARAYANASWAMY, R .
ANALYST, 1993, 118 (04) :317-322
[24]  
PEREZPAVON JL, 1992, ANAL CHEM, V64, P923
[25]  
RICHTER P, 1993, ANAL LETT, V26, P733
[26]   A simple and straightforward procedure for monitoring phenol compounds in waters by using UV solid phase transduction integrated in a continuous flow system [J].
Rama, MJR ;
Medina, AR ;
Díaz, AM .
MICROCHIMICA ACTA, 2003, 141 (3-4) :143-148
[27]  
RUEDASRAMA MJ, 2003, ANAL CHIM ACTA, V482, P209
[28]   A flow-through solid phase UV spectrophotometric biparameter sensor for the sequential determination of ascorbic acid and paracetamol [J].
Ruiz-Medina, A ;
Fernández-de Córdova, ML ;
Ayora-Cañada, MJ ;
Pascual-Reguera, MI ;
Molina-Díaz, A .
ANALYTICA CHIMICA ACTA, 2000, 404 (01) :131-139
[29]  
RUIZMEDINA A, 1999, FRESEN J ANAL CHEM, V365, P619
[30]  
RUZICKA J, 1985, ANAL CHIM ACTA, V173, P3