Voltammetry and EQCM investigation of glutathione monolayer and its complexation with Cu2+

被引:30
作者
Fang, C [1 ]
Zhou, XY [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
关键词
complexation; Cu2+; glutathione; voltammetry; EQCM;
D O I
10.1002/elan.200302737
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The glutathione (GSH) self-assembled monolayer and its compexlation with Cu2+ were studied by using voltammetry and EQCM. It was found that the monolayer could rearrange during the redox process Of Cu2+/Cu+. The protonating, or not, of the carboxyl terminates of the adsorpted GSH molecules influence the compexlation interaction significantly for they are the key binding sites. The GSH monolayer had the capacity to accumulate Cu2+ and the monolayer modified gold electrode was employed to detect the low levels of Cu2+ with a limit of 1.0 x 10(-10) mol L-1.
引用
收藏
页码:1632 / 1638
页数:7
相关论文
共 31 条
[21]   AN ION-GATE RESPONSE OF THE GLUTATHIONE MONOLAYER ASSEMBLY FORMED ON A GOLD ELECTRODE .1. THE EFFECT OF PH, K+ AND CA2+ [J].
TAKEHARA, K ;
IDE, Y ;
AIHARA, M ;
OBUCHI, E .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1992, 29 (01) :103-111
[22]   AN ION-GATE RESPONSE OF A GLUTATHIONE MONOLAYER ASSEMBLY HIGHLY SENSITIVE TO LANTHANIDE IONS [J].
TAKEHARA, K ;
AIHARA, M ;
UEDA, N .
ELECTROANALYSIS, 1994, 6 (11-12) :1083-1086
[23]   ELECTROCHEMICAL PROPERTIES OF THE GOLD ELECTRODE MODIFIED WITH MIXED MONOLAYER ASSEMBLY - THE EFFECT OF A POLAR HEAD GROUP ON THE KINETICS OF THE FE(CN)6(3-)FE(CN)6(4-) REACTION [J].
TAKEHARA, K ;
IDE, Y .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1992, 27 (03) :501-507
[24]   THERMODYNAMIC CONSIDERATIONS IN COORDINATION .25. FORMATION OF TERNARY COMPLEXES CONTAINING 2 DISSIMILAR METAL-IONS AND IMPLICATION FOR METAL-METAL STIMULATION PHENOMENA INVIVO [J].
TOUCHE, MLD ;
WILLIAMS, DR .
JOURNAL OF THE CHEMICAL SOCIETY-DALTON TRANSACTIONS, 1976, (14) :1355-1359
[25]   SELF-ASSEMBLED MONOLAYERS IN ELECTROANALYTICAL CHEMISTRY - APPLICATION OF OMEGA-MERCAPTOCARBOXYLIC ACID MONOLAYERS FOR ELECTROCHEMICAL DETERMINATION OF ULTRALOW LEVELS OF CADMIUM(II) [J].
TURYAN, I ;
MANDLER, D .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :58-63
[26]  
ULMAN A, 1996, CHEM REV, V96, P1287
[27]   The influence of surfactants on the electron-transfer reaction at self-assembled thiol monolayers modifying a gold electrode [J].
Wang, J ;
Zeng, BZ ;
Fang, C ;
Zhou, XY .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 484 (01) :88-92
[28]   Characterisation of gold electrodes modified with self-assembled monolayers of L-cysteine for the adsorptive stripping analysis of copper [J].
Yang, WR ;
Gooding, JJ ;
Hibbert, DB .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 516 (1-2) :10-16
[29]   Sub-ppt detection limits for copper ions with Gly-Gly-His modified electrodes [J].
Yang, WR ;
Jaramillo, D ;
Gooding, JJ ;
Hibbert, DB ;
Zhang, R ;
Willett, GD ;
Fisher, KJ .
CHEMICAL COMMUNICATIONS, 2001, (19) :1982-1983
[30]   Redox voltammetry of sub-parts per billion levels of Cu2+ at polyaspartate-modified gold electrodes [J].
Yang, WR ;
Gooding, JJ ;
Hibbert, DB .
ANALYST, 2001, 126 (09) :1573-1577