Sulfur-specific detection of impurities in cimetidine drug substance using liquid chromatography coupled to high resolution inductively coupled plasma mass spectrometry and electrospray mass spectrometry

被引:38
作者
Evans, EH
Wolff, JC
Eckers, C
机构
[1] Univ Plymouth, Dept Environm Sci, Plymouth Environm Res Ctr, Plymouth PL4 8AA, Devon, England
[2] GlaxoSmithKline, Harlow CM19 5AW, Essex, England
关键词
D O I
10.1021/ac0103017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of liquid chromatography coupled to sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) for the specific detection of sulfur-containing compounds is described. In the sulfur-containing drug substance cimetidine, structurally related impurities well below the 0.1 % mass fraction. level relative to the main drug substance could easily be detected. The structure of most of the impurities was confirmed by electrospray mass spectrometry (ESI-MS), and thus, the complementarity of the two techniques for drug analysis is shown. The limit of detection by SF-ICP-MS for cimetidine in solution was similar to4-20 ng.g(-1), but it was blank-limited.
引用
收藏
页码:4722 / 4728
页数:7
相关论文
共 21 条
[11]   High-performance liquid chromatography and inductively coupled plasma mass spectrometry (HPLC-ICP-MS) for the analysis of xenobiotic metabolites in rat urine: application to the metabolites of 4-bromoaniline [J].
Nicholson, JK ;
Lindon, JC ;
Scarfe, G ;
Wilson, ID ;
Abou-Shakra, F ;
Castro-Perez, J ;
Eaton, A ;
Preece, S .
ANALYST, 2000, 125 (02) :235-236
[12]   High-performance liquid chromatography linked to inductively coupled plasma mass spectrometry and orthogonal acceleration time-of-flight mass spectrometry for the simultaneous detection and identification of metabolites of 2-bromo-4-trifluoromethyl-[13C]-acetanilide in rat urine [J].
Nicholson, JK ;
Lindon, JC ;
Scarfe, GB ;
Wilson, ID ;
Abou-Shakra, F ;
Sage, AB ;
Castro-Perez, J .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1491-1494
[13]   Precise sulfur isotope ratio measurements in trace concentration of sulfur by inductively coupled plasma double focusing sector field mass spectrometry [J].
Prohaska, T ;
Latkoczy, C ;
Stingeder, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1501-1504
[14]  
STEFFENS TG, 1990, TRENDS BIOMEMBR BIOE, V1, P93
[15]  
Stuewer D, 1998, J MASS SPECTROM, V33, P579, DOI 10.1002/(SICI)1096-9888(199807)33:7<579::AID-JMS688>3.0.CO
[16]  
2-W
[17]   Inductively coupled plasma mass spectrometric detection for chromatography and capillary electrophoresis [J].
Sutton, K ;
Sutton, RMC ;
Caruso, JA .
JOURNAL OF CHROMATOGRAPHY A, 1997, 789 (1-2) :85-126
[18]   Measurement of trace elements in proteins extracted from liver by size exclusion chromatography-inductively coupled plasma-mass spectrometry with a magnetic sector mass spectrometer [J].
Wang, J ;
Dreessen, D ;
Wiederin, DR ;
Houk, RS .
ANALYTICAL BIOCHEMISTRY, 2001, 288 (01) :89-96
[19]   Analysis of protein phosphorylation by capillary liquid chromatography coupled to element mass spectrometry with 31P detection and to electrospray mass spectrometry [J].
Wind, M ;
Edler, M ;
Jakubowski, N ;
Linscheid, M ;
Wesch, H ;
Lehmann, WD .
ANALYTICAL CHEMISTRY, 2001, 73 (01) :29-35
[20]  
Xu KY, 1999, BIOMED CHROMATOGR, V13, P455, DOI 10.1002/(SICI)1099-0801(199911)13:7<455::AID-BMC911>3.0.CO