Low-Dose Computed Tomography Coronary Angiography With Prospective Electrocardiogram Triggering Feasibility in a Large Population

被引:76
作者
Buechel, Ronny R. [1 ]
Husmann, Lars [1 ]
Herzog, Bernhard A. [1 ]
Pazhenkottil, Aju P. [1 ]
Nkoulou, Rene [1 ]
Ghadri, Jelena R. [1 ]
Treyer, Valerie [1 ]
von Schulthess, Patrick [1 ]
Kaufmann, Philipp A. [1 ,2 ]
机构
[1] Univ Zurich Hosp, CH-8091 Zurich, Switzerland
[2] Univ Zurich, Zurich Ctr Integrat Human Physiol, Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
CT coronary angiography; feasibility; low radiation dose; prospective ECG triggering; CT ANGIOGRAPHY; ACQUISITION; EXPERIENCE; MSV;
D O I
10.1016/j.jacc.2010.08.634
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Objectives We sought to assess the feasibility of prospective electrocardiogram triggering for achieving low-dose computed tomography coronary angiography (CTCA) in a large population. Background Prospective electrocardiogram triggering dramatically reduces radiation exposure for CTCA but requires heart rate (HR) control to obtain diagnostic image quality. Its feasibility in daily clinical routine has therefore remained to be elucidated. Methods We evaluated 612 patients consecutively referred for CTCA by 64-slice computed tomography. Intravenous metoprolol (2 to 30 mg) was administered if necessary to achieve a target HR below 65 beats/min. Image quality was assessed on a semiquantitative 4-point scale for each coronary segment. Results Forty-six (7.5%) patients were deemed ineligible due to irregular heart rhythm (n = 19), insufficient response to metoprolol (n = 21), renal insufficiency (n = 3), or inability to follow breath-hold commands (n = 3). Mean effective radiation dose was 1.8 +/- 0.6 mSv with a diagnostic image quality in 96.2% of segments. Finally, low-dose CTCA allowed a firm diagnosis with regard to the presence or absence of coronary artery disease in 527 (86.1%) patients. Intravenous metoprolol to achieve an HR below 65 beats/min was used in 64.4% of patients. Incidence of nondiagnostic segments was inversely related to HR (r = -0.809, p < 0.001). Below an HR cutoff of 62 beats/min, only 1.2% of coronary segments were nondiagnostic. Conclusions Low-dose CTCA by electrocardiogram triggering is feasible in the vast majority of an every-day population. However, HR control is crucial, as an HR below 62 beats/min favors diagnostic image quality. (J Am Coll Cardiol 2011;57:332-6) (C) 2011 by the American College of Cardiology Foundation
引用
收藏
页码:332 / 336
页数:5
相关论文
共 15 条
[1]
Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition [J].
Achenbach, Stephan ;
Marwan, Mohamed ;
Ropers, Dieter ;
Schepis, Tiziano ;
Pflederer, Tobias ;
Anders, Katharina ;
Kuettner, Axel ;
Daniel, Werner G. ;
Uder, Michael ;
Lell, Michael M. .
EUROPEAN HEART JOURNAL, 2010, 31 (03) :340-346
[2]
Austen W G, 1975, Circulation, V51, P5
[3]
Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography [J].
Einstein, Andrew J. ;
Henzlova, Milena J. ;
Rajagopalan, Sanjay .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03) :317-323
[4]
Estimated Radiation Dose Associated With Cardiac CT Angiography [J].
Hausleiter, Joerg ;
Meyer, Tanja ;
Hermann, Franziska ;
Hadamitzky, Martin ;
Krebs, Markus ;
Gerber, Thomas C. ;
McCollough, Cynthia ;
Martinoff, Stefan ;
Kastrati, Adnan ;
Schoemig, Albert ;
Achenbach, Stephan .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (05) :500-507
[5]
First head-to-head comparison of effective radiation dose from low-dose 64-slice CT with prospective ECG-triggering versus invasive coronary angiography [J].
Herzog, B. A. ;
Wyss, C. A. ;
Husmann, L. ;
Gaemperli, O. ;
Valenta, I. ;
Treyer, V. ;
Landmesser, U. ;
Kaufmann, P. A. .
HEART, 2009, 95 (20) :1656-1661
[6]
Low-dose CT Coronary Angiography Using Prospective ECG-Triggering: Impact of Mean Heart Rate and Heart Rate Variability on Image Quality [J].
Herzog, Bernhard A. ;
Husmann, Lars ;
Burkhard, Nina ;
Valenta, Ines ;
Gaemperli, Oliver ;
Tatsugami, Fuminari ;
Wyss, Christophe A. ;
Landmesser, Ulf ;
Kaufmann, Philipp A. .
ACADEMIC RADIOLOGY, 2009, 16 (01) :15-21
[7]
Accuracy of low-dose computed tomography coronary angiography using prospective electrocardiogram-triggering: first clinical experience [J].
Herzog, Bernhard A. ;
Husmann, Lars ;
Burkhard, Nina ;
Gaemperli, Oliver ;
Valenta, Ines ;
Tatsugami, Fuminari ;
Wyss, Christophe A. ;
Landmesser, Ulf ;
Kaufmann, Philipp A. .
EUROPEAN HEART JOURNAL, 2008, 29 (24) :3037-3042
[8]
Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography [J].
Hsieh, Jiang ;
Londt, John ;
Vass, Melissa ;
Li, Jay ;
Tang, Xiangyang ;
Okerlund, Darin .
MEDICAL PHYSICS, 2006, 33 (11) :4236-4248
[9]
Coronary angiography with low-dose computed tomography at 1.4 mSv [J].
Husmann, Lars ;
Valenta, Ines ;
Kaufmann, Philipp A. .
HERZ, 2008, 33 (01) :75-75
[10]
Husmann L, 2008, EUR HEART J, V29, P191, DOI 10.1093/eurheartj/ehm613