Rapid aortic wave velocity measurement with MR imaging

被引:21
作者
Itskovich, VV
Kraft, KA
Fei, DY
机构
[1] Virginia Commonwealth Univ, Med Coll Virginia, Dept Radiol, Richmond, VA 23298 USA
[2] Virginia Commonwealth Univ, Med Coll Virginia, Dept Biomed Engn, Richmond, VA 23298 USA
关键词
aorta; flow dynamics; MR; magnetic resonance (MR); vascular studies; test objects;
D O I
10.1148/radiology.219.2.r01ap40551
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The utility of a one-dimensional magnetic resonance (MR) sequence to rapidly and accurately measure wave velocity in vivo was evaluated. Studies were conducted in the thoracic aortas of 20 healthy subjects of varying age, and the MR method was validated in a compliant tube model. Aortic wave velocity ranged from 3.8 to 9.7 m/sec and demonstrated a positive correlation with subjects' age. Peak blood velocity ranged from 47 to 125 cm/sec and exhibited a strong negative correlation with subjects' age.
引用
收藏
页码:551 / 557
页数:7
相关论文
共 21 条
[1]   EFFECTS OF AGING ON CHANGING ARTERIAL COMPLIANCE AND LEFT-VENTRICULAR LOAD IN A NORTHERN CHINESE URBAN-COMMUNITY [J].
AVOLIO, AP ;
CHEN, SG ;
WANG, RP ;
ZHANG, CL ;
LI, MF ;
OROURKE, MF .
CIRCULATION, 1983, 68 (01) :50-58
[2]   PULSEWAVE VELOCITY-MEASUREMENT USING A NEW REAL-TIME MR-METHOD [J].
BOCK, M ;
SCHAD, LR ;
MULLER, E ;
LORENZ, WJ .
MAGNETIC RESONANCE IMAGING, 1995, 13 (01) :21-29
[3]   Accuracy of arterial pulse-wave velocity measurement using MR [J].
Bolster, BD ;
Atalar, E ;
Hardy, CJ ;
McVeigh, ER .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04) :878-888
[4]  
BRACEWELL RN, 1978, FOURIER TRANSFORM IT, P98
[5]   QUANTITATIVE MEASUREMENT OF VELOCITY AT MULTIPLE POSITIONS USING COMB EXCITATION AND FOURIER VELOCITY ENCODING [J].
DUMOULIN, CL ;
DOORLY, DJ ;
CARO, CG .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (01) :44-52
[6]   THE MODULATION THEOREM IN TAILORED RADIOFREQUENCY EXCITATION AND ITS APPLICATION TO A NOTCH FILTER [J].
GONZALEZMENDEZ, R ;
ENGESETH, H ;
GIBSON, AAB ;
DEOLIVARES, J ;
LITT, L ;
JAMES, TL .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (02) :308-313
[7]   Pencil excitation with interleaved Fourier velocity encoding: NMR measurement of aortic distensibility [J].
Hardy, CJ ;
Bolster, BD ;
McVeigh, ER ;
Iben, IET ;
Zerhouni, EA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (06) :814-819
[8]   NONINVASIVE DETERMINATION OF AGE-RELATED-CHANGES IN THE HUMAN ARTERIAL PULSE [J].
KELLY, R ;
HAYWARD, C ;
AVOLIO, A ;
OROURKE, M .
CIRCULATION, 1989, 80 (06) :1652-1659
[9]   In vitro validation of rapid MR measurement of wave velocity [J].
Kraft, KA ;
Fatouros, PP ;
Corwin, FD ;
Fei, DY .
JOURNAL OF MAGNETIC RESONANCE, 1997, 126 (01) :103-109
[10]   ARTERIAL WAVE REFLECTION IN HEART-FAILURE [J].
LASKEY, WK ;
KUSSMAUL, WG .
CIRCULATION, 1987, 75 (04) :711-722