Determination of endocrine disruptors in environmental waters using poly(acrylamide-vinylpyridine) monolithic capillary for in-tube solid-phase microextraction coupled to high-performance liquid chromatography with fluorescence detection

被引:41
作者
Fan, Y [1 ]
Zhang, M [1 ]
Da, SL [1 ]
Feng, YQ [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
关键词
D O I
10.1039/b502311d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the determination of endocrine disruptors, bisphenol A and 17 alpha-ethinylestradiol, in environmental water samples was developed using in-tube solid-phase microextraction followed by liquid chromatography and fluorescence detection. A poly(acrylamide-vinylpyridine) monolithic capillary column was applied as the extraction media in view of its greater phase ratio than open-tubular capillaries and thus higher extraction efficiency. After optimizing the extraction conditions, bisphenol A and 17 alpha-ethinylestradiol were extracted directly from water samples in a wide dynamic linear range of 0.5-1000 ng mL(-1), with the detection limits obtained as 0.064 and 0.12 ng mL(-1), respectively. The precision of the method was satisfactory with the intraday and interday RSD values smaller than 7.2%. Environmental water samples of different sources were successfully analyzed with the presented method and the monolithic capillary was proved to be robust and reusable in analyzing real water samples.
引用
收藏
页码:1065 / 1069
页数:5
相关论文
共 27 条
[1]   Trace analysis of technical nonylphenol, bisphenol A and 17α-ethinylestradiol in wastewater using solid-phase microextraction and gas chromatography-mass spectrometry [J].
Braun, P ;
Moeder, M ;
Schrader, S ;
Popp, P ;
Kuschk, P ;
Engewald, W .
JOURNAL OF CHROMATOGRAPHY A, 2003, 988 (01) :41-51
[2]   Determination of steroid sex hormones and related synthetic compounds considered as endocrine disrupters in water by liquid chromatography-diode array detection-mass spectrometry [J].
de Alda, MJL ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 2000, 892 (1-2) :391-406
[3]   In-tube solid-phase microextraction with poly(methacrylic acidethylene glycol dimethacrylate) monolithic capillary for direct high-performance liquid chromatographic determination of ketamine in urine samples [J].
Fan, Y ;
Feng, YQ ;
Da, SL ;
Gao, XP .
ANALYST, 2004, 129 (11) :1065-1069
[4]   Poly (methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary for in-tube solid phase microextraction coupled to high performance liquid chromatography and its application to determination of basic drugs in human serum [J].
Fan, Y ;
Feng, YQ ;
Da, SL ;
Shi, ZG .
ANALYTICA CHIMICA ACTA, 2004, 523 (02) :251-258
[5]   Automated in-tube solid-phase microextraction-high-performance liquid chromatography for carbamate pesticide analysis [J].
Gou, YN ;
Eisert, R ;
Pawliszyn, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 873 (01) :137-147
[6]   Analysis of steroid hormones in effluents of wastewater treatment plants by liquid chromatography-tandem mass spectrometry [J].
Ingrand, V ;
Herry, G ;
Beausse, J ;
de Roubin, MR .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1020 (01) :99-104
[7]  
Kataoka H, 2002, J SEP SCI, V25, P77, DOI 10.1002/1615-9314(20020101)25:1/2<77::AID-JSSC77>3.0.CO
[8]  
2-3
[10]   Trace analysis of phenolic xenoestrogens in water samples by stir bar sorptive extraction with in situ derivatization and thermal desorption-gas chromatography-mass spectrometry [J].
Kawaguchi, M ;
Inoue, K ;
Yoshimura, M ;
Sakui, N ;
Okanouchi, N ;
Ito, R ;
Yoshimura, Y ;
Nakazawa, H .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1041 (1-2) :19-26