Four-dimensional treatment planning for stereotactic body radiotherapy

被引:129
作者
Guckenberger, Matthias
Wilbert, Juergen
Krieger, Thomas
Richter, Anne
Baier, Kurt
Meyer, Juergen
Flentje, Michael
机构
[1] Univ Wurzburg, Dept Radiat Oncol, D-97080 Wurzburg, Germany
[2] Univ Canterbury, Dept Phys & Astron, Christchurch 1, New Zealand
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2007年 / 69卷 / 01期
关键词
stereotactic body radiotherapy; SBRT; four-dimensional respiratory correlated computed tomography; 4D-CT; nonrigid deformable image registration; tumor breathing motion;
D O I
10.1016/j.ijrobp.2007.04.074
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate the influence of tumor motion on the calculation of four-dimensional (4D) dose distributions of the gross tumor volume (GTV) in pulmonary stereotactic body radiotherapy. Methods and Materials: For 7 patients with eight pulmonary tumors, a respiratory-correlated 4D-computed tomography study was acquired. The internal target volume was the sum of all tumor positions in the planning 4D-computed tomography study, and a 5-mm margin was used for generation of the planning target volume. Three-dimensional (3D) treatment plans were generated with a dose prescription of 3 x 12.5 Gy to the planning target volume enclosing the 65% and 80% isodose. After model-based nonrigid image registration, the 4D dose distributions were calculated. Results: No significant difference was found in the dose to the GTV with the tumor in the end-exhalation, end-inhalation, or mid-ventilation phase of the breathing cycle. The high-dose region was confined to the solid tumor, and lower doses were delivered to the surrounding pulmonary tissue of lower density. This nonstatic, variant dose distribution increased the 4D dose to the GTV by 6.2%, on average, compared with calculations using on a static dose distribution during the breathing cycle. The 4D accumulation resulted in a biologic effective dose (BED) of 143 8 Gy and 106 4 Gy to the GTV in the plan-65% and plan-80%, respectively. The dose to the ipsilateral lung was not different between the 3D and 4D dose calculations or between plan-65% and plan-80%. Conclusions: In this study, the dose to the GTV was not decreased or blurred in the 4D plan compared with the 3D plan. The 3D doses to the GTV, internal target volume, and dose at the isocenter were good approximations of the 4D dose calculations. The 3D dose at the planning target volume margin underestimated the 4D dose significantly. (c) 2007 Elsevier Inc.
引用
收藏
页码:276 / 285
页数:10
相关论文
共 50 条
[1]   A COMPUTERIZED SYSTEM FOR THE ELASTIC MATCHING OF DEFORMED RADIOGRAPHIC IMAGES TO IDEALIZED ATLAS IMAGES [J].
BAJCSY, R ;
LIEBERSON, R ;
REIVICH, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (04) :618-625
[2]   Stereotactic body radiation therapy for nonmetastatic lung cancer: An analysis of 75 patients treated over 5 years [J].
Beitler, Jonathan J. ;
Badine, Edgard A. ;
El-Sayah, Danny ;
Makara, Denise ;
Friscia, Phillip ;
Silverman, Phillip ;
Terjanian, Terenig .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (01) :100-106
[3]   STEREOTAXIC HIGH-DOSE FRACTION RADIATION-THERAPY OF EXTRACRANIAL TUMORS USING AN ACCELERATOR - CLINICAL-EXPERIENCE OF THE FIRST 31 PATIENTS [J].
BLOMGREN, H ;
LAX, I ;
NASLUND, I ;
SVANSTROM, R .
ACTA ONCOLOGICA, 1995, 34 (06) :861-870
[4]   Accuracy of finite element model-based multi-organ deformable image registration [J].
Brock, KK ;
Sharpe, MB ;
Dawson, LA ;
Kim, SM ;
Jaffray, DA .
MEDICAL PHYSICS, 2005, 32 (06) :1647-1659
[5]   The effect of set-up uncertainties, contour changes, and tissue inhomogeneities on target dose-volume histograms [J].
Cho, BCJ ;
van Herk, M ;
Mijnheer, BJ ;
Bartelink, H .
MEDICAL PHYSICS, 2002, 29 (10) :2305-2318
[6]   Four-dimensional proton treatment planning for lung tumors [J].
Engelsman, M ;
Rietzel, E ;
Kooy, HM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (05) :1589-1595
[7]   How much margin reduction is possible through gating or breath hold? [J].
Engelsman, M ;
Sharp, GC ;
Bortfeld, T ;
Onimaru, R ;
Shirato, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (03) :477-490
[8]   Conformity index:: A review [J].
Feuvret, L ;
Noël, G ;
Mazeron, JJ ;
Bey, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (02) :333-342
[9]   Estimation of the delivered patient dose in lung IMRT treatment based on deformable registration of 4D-CT data and Monte Carlo simulations [J].
Flampouri, Stella ;
Jiang, Steve B. ;
Sharp, Greg C. ;
Wolfgang, John ;
Patel, Abhijit A. ;
Choi, Noah C. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (11) :2763-2779
[10]   Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning [J].
Ford, EC ;
Mageras, GS ;
Yorke, E ;
Ling, CC .
MEDICAL PHYSICS, 2003, 30 (01) :88-97