Phantom evaluation of simultaneous thallium-201/technetium-99m aquisition in single-photon emission tomography

被引:14
作者
Cao, ZJ
Chen, CC
Maunoury, C
Holder, LE
Abraham, TC
Tehan, A
机构
[1] Department of Diagnostic Radiology, Univ. of Maryland Medical Center, Baltimore, MD
[2] Department of Diagnostic Radiology, Univ. of Maryland Medical Center, Baltimore, MD 21201-1595
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1996年 / 23卷 / 11期
关键词
single-photon emission tomography; reconstruction; simultaneous dual-isotope acquisition;
D O I
10.1007/BF01254477
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study investigated downscatter effects in cardiac single-photon emission tomographic studies with simultaneous thallium-201/technetium-99m acquisition, and evaluated a previously proposed subtraction technique for downscatter compensation, Ten studies were carried out with different defect sizes and locations and varying activity distributions using four energy windows: 70+/-10% keV, 140+/-10% keV, 100+/-10% KeV, and 103+/-16% keV, The subtraction technique used the 100- or 103-keV data to remove scattered Tc-99m counts from the 70-keV data, The size and contrast of infarcts in the dual-isotope 70-keV image were artificially decreased compared to those in the 140-keV image, caused by scattered Tc-99m counts that were comparable to the primary Tl-201 counts in the 70-keV window. The subtraction technique produced larger defects and more heterogeneous activity in the myocardial wall in dual-isotope 70-keV images compared to the corresponding Tl-201-only images. These artifacts were caused by the markedly different spatial distributions of scattered Tc-99m counts in the 100-keV (or 103-keV) window as compared with the 70-keV window. It is concluded that scattered Tc-99m photons may cause overestimation of ischemia and myocardial viability in simultaneous dual-isotope patient studies. The proposed subtraction technique was inaccurate and produced image artifacts. Adequate downscatter compensation methods must be developed before applying simultaneous Tl-201/Tc-99m acquisition in clinical practice.
引用
收藏
页码:1514 / 1520
页数:7
相关论文
共 14 条
[1]   TECHNETIUM 99M SESTAMIBI IN THE ASSESSMENT OF CHRONIC CORONARY-ARTERY DISEASE [J].
BERMAN, DS ;
KIAT, H ;
VANTRAIN, K ;
GARCIA, E ;
FRIEDMAN, J ;
MADDAHI, J .
SEMINARS IN NUCLEAR MEDICINE, 1991, 21 (03) :190-212
[2]   SEPARATE ACQUISITION REST THALLIUM-201/STRESS TC-99M SESTAMIBI DUAL-ISOTOPE MYOCARDIAL PERFUSION SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY - A CLINICAL VALIDATION-STUDY [J].
BERMAN, DS ;
KIAT, H ;
FRIEDMAN, JD ;
WANG, FP ;
VANTRAIN, K ;
MATZER, L ;
MADDAHI, J ;
GERMANO, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (05) :1455-1464
[3]  
DEPUEY EG, 1993, J NUCL MED, V34, P2006
[4]   TECHNICAL ASPECTS OF MYOCARDIAL SPECT IMAGING WITH TC-99M SESTAMIBI [J].
GARCIA, EV ;
COOKE, CD ;
VANTRAIN, KF ;
FOLKS, R ;
PEIFER, J ;
DEPUEY, EG ;
MADDAHI, J ;
ALAZRAKI, N ;
GALT, J ;
EZQUERRA, N ;
ZIFFER, J ;
AREEDA, J ;
BERMAN, DS .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (13) :E23-E31
[5]  
GERMANO G, 1994, J NUCL MED, V35, P356
[6]  
HADEMENOS G, 1992, IEEE MED IM, P1083
[7]  
KIAT H, 1994, J NUCL MED, V35, P542
[8]   A NEW DUAL-ISOTOPE CONVOLUTION CROSS-TALK CORRECTION METHOD - A TL-201 TC-99M SPECT CARDIAC PHANTOM STUDY [J].
KNESAUREK, K .
MEDICAL PHYSICS, 1994, 21 (10) :1577-1583
[9]  
LOWE VJ, 1993, J NUCL MED, V34, P1998
[10]  
MATZER L, 1992, Journal of the American College of Cardiology, V19, p127A