Robust dynamic susceptibility contrast MR perfusion using 4D nonlinear noise filters

被引:15
作者
Kosior, Jayme Cameron [1 ,2 ]
Kosior, Robert Karl [1 ,2 ]
Frayne, Richard [1 ,2 ,3 ]
机构
[1] Univ Calgary, Foothills Med Ctr, Seaman Family MR Res Ctr, Dept Radiol, Calgary, AB T2N 2T9, Canada
[2] Univ Calgary, Dept Elect & Comp Engn, Calgary, AB, Canada
[3] Univ Calgary, Dept Clin Neurosci, Calgary, AB, Canada
关键词
dynamic susceptibility contrast (DSC); cerebral blood flow (CBF); spatiotemporal noise filtering; perfusion phantom; acute ischemic stroke;
D O I
10.1002/jmri.21219
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate if 4D (simultaneous space and time) nonlinear filtering techniques can produce more robust cerebral blood flow (CBF) estimates by reducing noise in acquired dynamic susceptibility contrast (DSC) MR perfusion data. Materials and Methods: A digital anthropomorphic brain per-fusion phantom was constructed to analyze filter performance by: 1) deriving anthropomorphic tissue volume fractions from a human subject and 2) simulating DSC-MR perfusion signals for voxels with mixed tissue for various signal-to-noise ratios (SNRs). DSC-MR data for 11 acute ischemic stroke patients were also acquired at 3T. CBF maps cross-calibrated so that normal white matter CBF was 22 mL/minute/100 g were produced from DSC-MR data without filtering and from 4D-Gaussian and 4D-bilateral noise-filtered DSC-MR data. Results: The nonlinear 4D-bilateral filter yielded the lowest CBF root-mean square error (RMSE) in the phantom experiments with noise (average RMSE across all tissues regions for no filtering. 4D-Gaussian, and 4D-bilateral was 5.3 mL/ minute/ 100 g, 6.2 mL/minute/100 g, and 4.0 mL/minute/100 g. respectively) and had the best image quality in both the phantom and patient data. Conclusion: Nonlinear 4D noise filters are better suited to the 4D nature of DSC-MR data. Linear spatial filters are not appropriate and can produce larger CBF errors than without filtering.
引用
收藏
页码:1514 / 1522
页数:9
相关论文
共 28 条
[1]   Perfusion quantification using Gaussian process deconvolution [J].
Andersen, IK ;
Szymkowiak, A ;
Rasmussen, CE ;
Hanson, LG ;
Marstrand, JR ;
Larsson, HBW ;
Hansen, LK .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) :351-361
[2]   A common framework for nonlinear diffusion, adaptive smoothing, bilateral filtering and mean shift [J].
Barash, D ;
Comaniciu, D .
IMAGE AND VISION COMPUTING, 2004, 22 (01) :73-81
[3]   Defining a local arterial input function for perfusion MRI using independent component analysis [J].
Calamante, F ;
Morup, M ;
Hansen, LK .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) :789-797
[4]   Quantification of bolus-tracking MRI: Improved characterization of the tissue residue function using Tikhonov regularization [J].
Calamante, F ;
Gadian, DG ;
Connelly, A .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (06) :1237-1247
[5]   The impact of partial-volume effects in dynamic susceptibility contrast magnetic resonance perfusion imaging [J].
Chen, JJ ;
Smith, MR ;
Frayne, R .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (03) :390-399
[6]   Advantages of frequency-domain modeling in dynamic-susceptibility contrast magnetic resonance cerebral blood flow quantification [J].
Chen, JJ ;
Smith, MR ;
Frayne, R .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (03) :700-707
[7]   NONLINEAR ANISOTROPIC FILTERING OF MRI DATA [J].
GERIG, G ;
KUBLER, O ;
KIKINIS, R ;
JOLESZ, FA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (02) :221-232
[8]   Cerebral vascular mean transit time in healthy humans: a comparative study with PET and dynamic susceptibility contrast-enhanced MRI [J].
Ibaraki, Masanobu ;
Ito, Hiroshi ;
Shimosegawa, Eku ;
Toyoshima, Hideto ;
Ishigame, Keiichi ;
Takahashi, Kazuhiro ;
Kanno, Iwao ;
Miura, Shuichi .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2007, 27 (02) :404-413
[9]   Assessment of cerebral hemodynamics and oxygen extraction using dynamic susceptibility contrast and spin echo blood oxygenation level-dependent magnetic resonance imaging: applications to carotid stenosis patients [J].
Kavec, M ;
Usenius, JP ;
Tuunanen, PI ;
Rissanen, A ;
Kauppinen, RA .
NEUROIMAGE, 2004, 22 (01) :258-267
[10]   Perfusion measurements of the brain:: using dynamic CT for the quantitative assessment of cerebral ischemia in acute stroke [J].
Klotz, E ;
König, M .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 30 (03) :170-184