Electrochemical Glucose Sensors-Developments Using Electrostatic Assembly and Carbon Nanotubes for Biosensor Construction

被引:120
作者
Harper, Alice [2 ]
Anderson, Mark R. [1 ]
机构
[1] Univ Colorado, Dept Chem, Denver, CO 80217 USA
[2] Berry Coll, Dept Chem, Mt Berry, GA 30149 USA
关键词
glucose oxidase; electrochemical sensors; electrostatic assembly; carbon nanotubes; ENZYME ELECTRODE; REDOX POLYMER; PRUSSIAN-BLUE; HYDROGEN-PEROXIDE; TRANSFER KINETICS; LAYER ADSORPTION; MULTILAYER FILMS; COMPOSITE FILM; OXIDASE; MEDIATOR;
D O I
10.3390/s100908248
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In 1962, Clark and Lyons proposed incorporating the enzyme glucose oxidase in the construction of an electrochemical sensor for glucose in blood plasma. In their application, Clark and Lyons describe an electrode in which a membrane permeable to glucose traps a small volume of solution containing the enzyme adjacent to a pH electrode, and the presence of glucose is detected by the change in the electrode potential that occurs when glucose reacts with the enzyme in this volume of solution. Although described nearly 50 years ago, this seminal development provides the general structure for constructing electrochemical glucose sensors that is still used today. Despite the maturity of the field, new developments that explore solutions to the fundamental limitations of electrochemical glucose sensors continue to emerge. Here we discuss two developments of the last 15 years; confining the enzyme and a redox mediator to a very thin molecular films at electrode surfaces by electrostatic assembly, and the use of electrodes modified by carbon nanotubes (CNTs) to leverage the electrocatalytic effect of the CNTs to reduce the oxidation overpotential of the electrode reaction or for the direct electron transport to the enzyme.
引用
收藏
页码:8248 / 8274
页数:27
相关论文
共 133 条
[1]   Biosensors for in vivo glucose measurement: can we cross the experimental stage [J].
Abel, PU ;
von Woedtke, T .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) :1059-1070
[2]   Fabrication of ultra-thin polypyrrole-glucose oxidase film from supporting electrolyte-free monomer solution for potentiometric biosensing of glucose [J].
Adeloju, SB ;
Moline, AN .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (03) :133-139
[3]   THE DESIGN OF ENZYME SENSORS BASED ON THE ENZYME STRUCTURE [J].
ALVAREZICAZA, M ;
KALISZ, HM ;
HECHT, HJ ;
AUMANN, KD ;
SCHOMBURG, D ;
SCHMID, RD .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (08) :735-742
[4]   Modulation of Single-Walled Carbon Nanotube Photoluminescence by Hydrogel Swelling [J].
Barone, Paul W. ;
Yoon, Hyeonseok ;
Ortiz-Garcia, Rene ;
Zhang, Jingqing ;
Ahn, Jin-Ho ;
Kim, Jong-Ho ;
Strano, Michael S. .
ACS NANO, 2009, 3 (12) :3869-3877
[5]   ENZYME SWITCH RESPONSIVE TO GLUCOSE [J].
BARTLETT, PN ;
BIRKIN, PR .
ANALYTICAL CHEMISTRY, 1993, 65 (08) :1118-1119
[6]   THEORETICAL TREATMENT OF DIFFUSION AND KINETICS IN AMPEROMETRIC IMMOBILIZED ENZYME ELECTRODES .1. REDOX MEDIATOR ENTRAPPED WITHIN THE FILM [J].
BARTLETT, PN ;
PRATT, KFE .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 397 (1-2) :61-78
[7]   ENZYME CATALYSIS AT HYDROGEL-MODIFIED ELECTRODES WITH SOLUBLE REDOX MEDIATOR [J].
BATTAGLINI, F ;
CALVO, EJ .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1994, 90 (07) :987-995
[8]  
Bertrand P, 2000, MACROMOL RAPID COMM, V21, P319, DOI 10.1002/(SICI)1521-3927(20000401)21:7<319::AID-MARC319>3.0.CO
[9]  
2-7
[10]   IMMOBILIZATION OF GLUCOSE-OXIDASE ON A CARBON SURFACE DERIVATIZED BY ELECTROCHEMICAL REDUCTION OF DIAZONIUM SALTS [J].
BOURDILLON, C ;
DELAMAR, M ;
DEMAILLE, C ;
HITMI, R ;
MOIROUX, J ;
PINSON, J .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 336 (1-2) :113-123