Novel low power reduced pressure inductively coupled plasma ionization source for mass spectrometric detection of organotin species

被引:21
作者
Waggoner, JW
Belkin, M
Sutton, KL
Caruso, JA [1 ]
Fannin, HB
机构
[1] Univ Cincinnati, Dept Chem, Cincinnati, OH 45221 USA
[2] Murray State Univ, Dept Chem, Murray, KY 42071 USA
关键词
reduced pressure plasma; helium inductively coupled plasma; mass spectrometry; capillary gas chromatography; organotin compounds; speciation;
D O I
10.1039/a802222d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel, low power, reduced pressure, helium inductively coupled plasma source (LP/RP-He-ICP), operated at an estimated incident rf power of 12-15 W and pressures ranging from 0.37 to 1.2 mbar, was interfaced with mass spectrometry and coupled with gas chromatography for the separation and detection of three organotin species, viz., tetraethyltin (TET), trimethyl(phenyl)tin (TMPT) and tetrabutyltin (TBT), Limits of detection las tin) for TET, TMPT and TBT were 0.12, 0,35, and 0.56 pg, respectively. Characteristic mass spectra matching established library spectra were obtained at low nanogram levels for TET,TMPT,TBT and tetramethyltin (TMT), The potential of the source to provide tunable fragmentation was also investigated.
引用
收藏
页码:879 / 883
页数:5
相关论文
共 13 条
[1]  
BELKIN M, UNPUB ANNAL COMMUN
[2]   Radiofrequency glow discharge as an ion source for gas chromatography with mass spectrometric detection [J].
Belkin, MA ;
Olson, LK ;
Caruso, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (11) :1255-1261
[3]   EVALUATION OF LOW-PRESSURE INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY FOR THE ANALYSIS OF GASEOUS SAMPLES [J].
CASTILLANO, TM ;
GIGLIO, JJ ;
EVANS, EH ;
CARUSO, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (12) :1335-1340
[4]   FUNDAMENTAL-STUDIES OF THE SAMPLING PROCESS IN AN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETER .4. REPLACEMENT OF THE INDUCTIVELY COUPLED PLASMA WITH A HELIUM MICROWAVE-INDUCED PLASMA [J].
CHAMBERS, DM ;
CARNAHAN, JW ;
JIN, Q ;
HIEFTJE, GM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (13) :1745-1765
[5]   LOW-PRESSURE INDUCTIVELY-COUPLED PLASMA SOURCE FOR MASS-SPECTROMETRY [J].
EVANS, EH ;
CARUSO, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (03) :427-431
[6]   LOW-PRESSURE INDUCTIVELY-COUPLED PLASMA ION-SOURCE FOR MOLECULAR AND ATOMIC MASS-SPECTROMETRY [J].
EVANS, EH ;
PRETORIUS, W ;
EBDON, L ;
ROWLAND, S .
ANALYTICAL CHEMISTRY, 1994, 66 (20) :3400-3407
[7]   Solid phase microextraction as sample introduction technique for radio frequency glow discharge mass spectrometry [J].
Gorecki, T ;
Belkin, M ;
Caruso, J ;
Pawliszyn, J .
ANALYTICAL COMMUNICATIONS, 1997, 34 (10) :275-277
[8]  
JERRELL LJ, UNPUB APPL SPECTROSC
[9]   SOLID-STATE RADIOFREQUENCY-OSCILLATOR FOR OPTOGALVANIC SPECTROSCOPY - DETECTION OF NITRIC-OXIDE USING THE 2-0 OVERTONE TRANSITION [J].
MAY, RD ;
MAY, PH .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (09) :2242-2245
[10]   Feasibility study of low pressure inductively coupled plasma mass spectrometry for qualitative and quantitative speciation [J].
OConnor, G ;
Ebdon, L ;
Evans, EH ;
Ding, H ;
Olson, LK ;
Caruso, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (12) :1151-1161