Determination of retinol and retinyl esters in human plasma by high-performance liquid chromatography with automated column switching and ultraviolet detection

被引:28
作者
Hartmann, S
Froescheis, O [1 ]
Ringenbach, F
Wyss, R
Bucheli, F
Bischof, S
Bausch, J
Wiegand, UW
机构
[1] F Hoffmann La Roche & Co Ltd, Vitamins & Fine Chem Div, CH-4070 Basel, Switzerland
[2] F Hoffmann La Roche & Co Ltd, Div Pharmaceut, CH-4070 Basel, Switzerland
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2001年 / 751卷 / 02期
关键词
retinol; retinyl esters;
D O I
10.1016/S0378-4347(00)00481-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A HPLC method with automated column switching and UV detection is described for the simultaneous determination of retinol and major retinyl esters (retinyl palmitate, retinyl stearate, retinyl oleate and retinyl linoleate) in human plasma. Plasma (0.2 mi) was deproteinized by adding ethanol (1.5 mi) containing the internal standard retinyl propionate. Following centrifugation the supernatant was directly injected onto the pre-column packed with LiChrospher 100 RP-18 using 1.2% ammonium acetate-acetic acid-ethanol (80:1:20, v/v) as mobile phase. The elution strength of the ethanol containing sample solution was reduced by on-line supply of 1% ammonium acetate-acetic acid-ethanol (100:2:4, v/v). The retained retinol and retinyl esters were then transferred to the analytical column (Superspher 100 RP-18, endcapped) in the backflush mode and chromatographed under isocratic conditions using acetonitrile-methanol-ethanol-2-propanol (1:1:1:1, v/v) as mobile phase. Compounds of interest were detected at 325 nm. The method was linear in the range 2.5-2000 ng/ml with a limit of quantification for retinol and retinyl esters of 2.5 ng/ml. Mean recoveries from plasma were 93.4-96.5% for retinol (range 100-1000 ng/ml) and 92.7-96.0% for retinyl palmitate (range 5-1000 ng/ml). Inter-assay precision was less than or equal to5.1% and less than or equal to6.3% for retinol and retinyl palmitate, respectively. The method was successfully applied to more than 2000 human plasma samples from clinical studies. Endogenous levels of retinol and retinyl esters determined in female volunteers were in good accordance with published data. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:265 / 275
页数:11
相关论文
共 34 条
[1]   HPLC analysis of fat-soluble vitamins on standard and narrow bore columns with UV, electrochemical and particle beam MS detection [J].
Andreoli, R ;
Careri, M ;
Manini, P ;
Mori, G ;
Musci, M .
CHROMATOGRAPHIA, 1997, 44 (11-12) :605-612
[2]   SIMULTANEOUS DETERMINATION OF RETINOL, ALPHA-TOCOPHEROL AND RETINYL PALMITATE IN PLASMA OF PREMATURE NEWBORNS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BORTOLOTTI, A ;
LUCCHINI, G ;
BARZAGO, MM ;
STELLARI, F ;
BONATI, M .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 617 (02) :313-317
[3]   THE TERATOGENIC METABOLITES OF VITAMIN-A IN WOMEN FOLLOWING SUPPLEMENTS AND LIVER [J].
BUSS, NE ;
TEMBE, EA ;
PRENDERGAST, BD ;
RENWICK, AG ;
GEORGE, CF .
HUMAN & EXPERIMENTAL TOXICOLOGY, 1994, 13 (01) :33-43
[4]   HUMAN PLASMA ALL-TRANS-4-OXORETINOIC, 13-CIS-4-OXORETINOIC AND 13-CIS-4-OXORETINOIC ACID PROFILES DURING SUBCHRONIC VITAMIN-A SUPPLEMENTATION - COMPARISON TO RETINOL AND RETINYL ESTER PLASMA-LEVELS [J].
ECKHOFF, C ;
COLLINS, MD ;
NAU, H .
JOURNAL OF NUTRITION, 1991, 121 (07) :1016-1025
[5]  
ECKHOFF C, 1990, J LIPID RES, V31, P1445
[6]  
GIULIANO AR, 1993, METHOD ENZYMOL, V214, P94
[7]   SIMULTANEOUS DETERMINATION OF RETINYL ESTERS AND RETINOL IN HUMAN LIVERS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GOT, L ;
GOUSSON, T ;
DELACOUX, E .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1995, 668 (02) :233-239
[8]   Quantitative high-performance liquid chromatographic determination of retinoids in human serum using on-line solid-phase extraction and column switching - Determination of 9-cis-retinoic acid, 13-cis-retinoic acid, all-trans-retinoic acid, 4-oxo-all-trans-retinoic acid and 4-oxo-13-cis-retinoic acid [J].
Gundersen, TE ;
Lundanes, E ;
Blomhoff, R .
JOURNAL OF CHROMATOGRAPHY B, 1997, 691 (01) :43-58
[9]  
Gundersen TE, 1999, METHOD ENZYMOL, V299, P430
[10]   Retinol and retinyl ester concentrations in rat tissues during total parenteral nutrition [J].
Lespine, A ;
Periquet, B ;
Garcia, J ;
Ghisolfi, J ;
Thouvenot, JP .
JOURNAL OF NUTRITIONAL BIOCHEMISTRY, 1998, 9 (06) :316-323