Microbubble beam (MBB), a potential dispersion mechanism for multiphase gas-liquid microreactor systems

被引:11
作者
Doku, GN
Verboom, W
Reinhoudt, DN
van den Berg, A
机构
[1] Univ Twente, Lab MicroBiomed & Environm Technol, NL-7500 AE Enschede, Netherlands
[2] Univ Twente, Lab Supramol Chem & Technol, NL-7500 AE Enschede, Netherlands
[3] Univ Twente, MESA Res Inst, NL-7500 AE Enschede, Netherlands
关键词
D O I
10.1021/ie020915h
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Systems consisting of single and multiple micropipet tips mounted in a channel for the generation of microbubble beams (MBB, as a gas-liquid dispersion mechanism) in moving liquids were constructed in stainless steel housing with Pyrex windows on both sides of the housing for imaging. Pressure head effects were used to pump the liquid through the channel, while air obtained directly from a pressurized source was introduced through the micropipets into the channel perpendicular to the (main) liquid flow direction. The effects of the liquid velocity, gassupply pressure, pipet hole size, liquid temperature, liquid viscosity, pipet-liquid hydrophilicity, and multiple-pipet configurations on the bubble generation and the bubble size, quantity, and speed have been investigated. Reverse hydrophilicity is required of the pipet and the liquid so as to reduce gas-supply pressure requirements. Specific interfacial contact areas estimated were about 2-10 times larger than those reported until now in the literature for the microbubble columns employed in microreactor systems, and even far larger than those reported for conventional/traditional gas-liquid contacting equipment, suggesting a superior performance for the MBB dispersion technique in future microreactor applications. Multiple micropipet configuration, rather than one large pipet hole, is the recommended means of increasing the gas quantity requirements, with enough inter-pipet distances and pipet height differences so as to prevent bubble coalescence.
引用
收藏
页码:3721 / 3730
页数:10
相关论文
共 34 条
[1]   Integrated microfluidic system enabling (bio)chemical reactions with on-line MALDI-TOF mass spectrometry [J].
Brivio, M ;
Fokkens, RH ;
Verboom, W ;
Reinhoudt, DN ;
Tas, NR ;
Goedbloed, M ;
van den Berg, A .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :3972-3976
[2]   Development of a microreactor for chemical production [J].
Burns, JR ;
Ramshaw, C .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 1999, 77 (A3) :206-211
[3]  
DIETZSCH E, 2000, P 4 INT C MICR TECHN, P89
[4]   Further studies into the development of a micro-FIA (μFIA) system based on electroosmotic flow for the determination of phosphate as orthophosphate [J].
Doku, GN ;
Haswell, SJ .
ANALYTICA CHIMICA ACTA, 1999, 382 (1-2) :1-13
[5]   Simultaneous determination of lithium, sodium and potassium in blood serum by flame photometric flow-injection analysis [J].
Doku, GN ;
Gadzekpo, VPY .
TALANTA, 1996, 43 (05) :735-739
[6]   Electric field-induced mobilisation of multiphase solution systems based on the nitration of benzene in a micro reactor [J].
Doku, GN ;
Haswell, SJ ;
McCreedy, T ;
Greenway, GM .
ANALYST, 2001, 126 (01) :14-20
[7]   Characterization of mixing in micromixers by a test reaction:: Single mixing units and mixer arrays [J].
Ehrfeld, W ;
Golbig, K ;
Hessel, V ;
Löwe, H ;
Richter, T .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1999, 38 (03) :1075-1082
[8]  
EHRFELD W, 1999, P IMRET 3 IND PROSP, P364
[9]  
FOX RW, 1985, INTRO FLUID MECH, P304
[10]   Perfectly monodisperse microbubbling by capillary flow focusing -: art. no. 274501 [J].
Gañán-Calvo, AM ;
Gordillo, JM .
PHYSICAL REVIEW LETTERS, 2001, 87 (27)