Computer simulations of electrokinetic transport in microfabricated channel structures

被引:198
作者
Ermakov, SV [1 ]
Jacobson, SC [1 ]
Ramsey, JM [1 ]
机构
[1] Oak Ridge Natl Lab, Div Chem & Analyt Sci, Oak Ridge, TN 37831 USA
关键词
D O I
10.1021/ac980551w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A mathematical model describing electrokinetically driven mass transport phenomena in microfabricated chip devices is presented in this paper. The model accounts for principal material transport mechanisms such as electrokinetic migration (electrophoresis and electroosmosis) and diffusion. A computer code that implements the model is capable of simulating transport of materials during electrokinetic manipulation in 2-D channel structures. The computer code allows arbitrary channel geometries with various boundary conditions for the electric field and the sample concentration. Two fundamental microfluidic chip elements, a cross and a mixing tee, are of particular interest. An electrokinetic focusing experiment using a cross structure and mixing in a tee structure are simulated. Simulations revealed an optimum focusing voltage for which the ratio of sample concentration to sample width is maximized. They also verified that the mixing tee provides very accurate dilution/mixing characteristics for both charged and neutral samples. Good agreement between simulated and experimental data verified the accuracy of the mathematical model. © 1998 American Chemical Society.
引用
收藏
页码:4494 / 4504
页数:11
相关论文
共 57 条
[31]   HIGH-SPEED SEPARATIONS ON A MICROCHIP [J].
JACOBSON, SC ;
HERGENRODER, R ;
KOUTNY, LB ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1994, 66 (07) :1114-1118
[32]   PRECOLUMN REACTIONS WITH ELECTROPHORETIC ANALYSIS INTEGRATED ON A MICROCHIP [J].
JACOBSON, SC ;
HERGENRODER, R ;
MOORE, AW ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1994, 66 (23) :4127-4132
[33]   EFFECTS OF INJECTION SCHEMES AND COLUMN GEOMETRY ON THE PERFORMANCE OF MICROCHIP ELECTROPHORESIS DEVICES [J].
JACOBSON, SC ;
HERGENRODER, R ;
KOUTNY, LB ;
WARMACK, RJ ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1994, 66 (07) :1107-1113
[34]   MICROCHIP CAPILLARY ELECTROPHORESIS WITH AN INTEGRATED POSTCOLUMN REACTOR [J].
JACOBSON, SC ;
KOUTNY, LB ;
HERGENRODER, R ;
MOORE, AW ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1994, 66 (20) :3472-3476
[35]  
JANSSON M, 1989, HRC-J HIGH RES CHROM, V12, P797
[37]   Microchip electrophoretic immunoassay for serum cortisol [J].
Koutny, LB ;
Schmalzing, D ;
Taylor, TA ;
Fuchs, M .
ANALYTICAL CHEMISTRY, 1996, 68 (01) :18-22
[38]  
Kutter J, 1995, HRC-J HIGH RES CHROM, V18, P741
[39]   Integrated microchip device with electrokinetically controlled solvent mixing for isocratic and gradient elution in micellar electrokinetic chromatography [J].
Kutter, JP ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (24) :5165-5171
[40]  
Lamb H., 1945, HYDRODYNAMICS, V6th, P738