Concurrent validity and intrasession reliability of the IDEEA accelerometry system for the quantification of spatiotemporal gait parameters

被引:65
作者
Maffiuletti, Nicola A. [1 ]
Gorelick, Mark [1 ]
Quervain, Ines Kramers-de [1 ,2 ]
Bizzini, Mario [1 ]
Munzinger, Jeannette Petrich [1 ]
Tomasetti, Samuele [2 ]
Stacoff, Alex [2 ]
机构
[1] Schulthess Clin, Neuromusc Res, CH-8008 Zurich, Switzerland
[2] ETH, Biomech Lab, Zurich, Switzerland
关键词
accelerometers; stride; step; cadence;
D O I
10.1016/j.gaitpost.2007.01.003
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The aim of this pilot study was to evaluate concurrent validity and intrasession reliability of the IDEEA (Minisun, Fresno, CA) accelerometry system (and associated software) with force plate measurements for spatiotemporal gait variables recorded during normal walking. Ten healthy individuals were asked to walk at a self-selected comfortable speed, over five multicomponent force plates embedded into the walkway floor. For each trial, spatiotemporal gait parameters (single support time, cadence, speed, step and stride length) obtained by the force plates were compared to those recorded by IDEEA. Concurrent (criterion-related) validity between the two systems was analysed with intraclass correlation (ICC) (2, 1). Intrasession reliability was quantified by using coefficient of variations (CV) and ICC. For the ensemble of the parameters, ICC (2, 1) ranged between 0.998 (cadence) and 0.784 (step length right) (p < 0.001-0.01). However, speed, step length and stride length were significantly lower for IDEEA (similar to 7%; p < 0.001) compared to force plate data. Intrasession reliability of IDEEA was excellent, with CV lower than 5.7 and ICC higher than 0.961. The present accelerometry system demonstrated strong concurrent validity for the assessment of spatiotemporal gait parameters. However, spatial variables (stride and step length) and walking speed were significantly underestimated compared with analyses using force plates. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:160 / 163
页数:4
相关论文
共 10 条
[1]   Concurrent related validity of the GAITRite® walkway system for quantification of the spatial and temporal parameters of gait [J].
Bilney, B ;
Morris, M ;
Webster, K .
GAIT & POSTURE, 2003, 17 (01) :68-74
[2]   Test-retest reliability of trunk accelerometric gait analysis [J].
Henriksen, M ;
Lund, H ;
Moe-Nilssen, R ;
Bliddal, H ;
Danneskiod-Samsoe, B .
GAIT & POSTURE, 2004, 19 (03) :288-297
[3]   The use of accelerometry to detect heel contact events for use as a sensor in FES assisted walking [J].
Mansfield, A ;
Lyons, GM .
MEDICAL ENGINEERING & PHYSICS, 2003, 25 (10) :879-885
[4]   Acceleration patterns of the head and pelvis when walking on level and irregular surfaces [J].
Menz, HB ;
Lord, SR ;
Fitzpatrick, RC .
GAIT & POSTURE, 2003, 18 (01) :35-46
[5]   Test-retest reliability of trunk accelerometry during standing and walking [J].
Moe-Nilssen, R .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1998, 79 (11) :1377-1385
[6]  
MONAGHAN K, 2006, GAIT POSTURE
[7]  
OLSSON E, 1986, SCAND J REHABIL MED, P1
[8]   Reliability and validity of bilateral thigh and foot accelerometry measures of walking in healthy and hemiparetic subjects [J].
Saremi, Kaveh ;
Marehbian, Jon ;
Yan, Xiaohong ;
Regnaux, Jean-Philippe ;
Elashoff, Robert ;
Bussel, Bernard ;
Dobkin, Bruce H. .
NEUROREHABILITATION AND NEURAL REPAIR, 2006, 20 (02) :297-305
[9]   Ground reaction forces on stairs:: effects of stair inclination and age [J].
Stacoff, A ;
Diezi, C ;
Luder, G ;
Stüssi, E ;
Kramers-De Quervain, IA .
GAIT & POSTURE, 2005, 21 (01) :24-38
[10]   Improving energy expenditure estimation for physical activity [J].
Zhang, K ;
Pi-Sunyer, FX ;
Boozer, CN .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (05) :883-889