The use of accelerometry to detect heel contact events for use as a sensor in FES assisted walking

被引:115
作者
Mansfield, A [1 ]
Lyons, GM [1 ]
机构
[1] Univ Limerick, Dept Elect & Comp Engn, Biomed Elect Lab, Limerick, Ireland
关键词
FES; accelerometry; hemiplegia; gait events; sensors;
D O I
10.1016/S1350-4533(03)00116-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Current sensors for the control of functional electrical stimulation (FES) assisted walking in hemiplegic individuals are not wholly satisfactory, as they are either not implantable or ineffectual in the detection of heel contact events. This study describes the use of an accelerometer placed on the trunk to detect heel contact events of both legs based on the examination of the anterior-posterior horizontal acceleration signal. Four subjects wore an accelerometer over their lumbar spine. Footswitches placed on the sole of one foot recorded the heel contact and heel off times for that foot. The acceleration signal was reduced to a series of pulses by studying the negative-positive changes in acceleration. It was found that there was approximately a 150 ms delay between heel contact and the negative-positive change in acceleration. This delay was consistent across different walking speeds, but was different between subjects and when hemiplegic gait was simulated. Therefore, accelerometers placed on the trunk are valid sensors for the detection of heel contact events during FES assisted walking. (C) 2003 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:879 / 885
页数:7
相关论文
共 19 条
[1]   Temporal feature estimation during walking using miniature accelerometers: an analysis of gait improvement after hip arthroplasty [J].
Aminian, K ;
Rezakhanlou, K ;
De Andres, E ;
Fritsch, C ;
Leyvraz, PF ;
Robert, P .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (06) :686-691
[2]   THE USE OF A 4-CHANNEL ELECTRICAL STIMULATOR AS AN AMBULATORY AID FOR PARAPLEGIC PATIENTS [J].
BAJD, T ;
KRALJ, A ;
TURK, R ;
BENKO, H ;
SEGA, J .
PHYSICAL THERAPY, 1983, 63 (07) :1116-1120
[3]  
BAKER LL, 1999, CLIN ELECTROTHERAPY, P143
[4]  
BRANDELL BR, 1982, AM J PHYS MED REHAB, V61, P279
[5]   Experience of clinical use of the Odstock dropped foot stimulator [J].
Burridge, J ;
Taylor, P ;
Hagan, S ;
Swain, I .
ARTIFICIAL ORGANS, 1997, 21 (03) :254-260
[6]   The effects of common peroneal stimulation on the effort and speed of walking: a randomized controlled trial with chronic hemiplegic patients [J].
Burridge, JH ;
Taylor, PN ;
Hagan, SA ;
Wood, DE ;
Swain, ID .
CLINICAL REHABILITATION, 1997, 11 (03) :201-210
[7]  
COZEAN CD, 1988, ARCH PHYS MED REHAB, V69, P401
[8]   MEASUREMENT OF GAIT BY ACCELEROMETER AND WALKWAY - A COMPARISON STUDY [J].
CURRIE, G ;
RAFFERTY, D ;
DUNCAN, G ;
BELL, F ;
EVANS, AL .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (06) :669-670
[9]   Functional electrostimulation in poststroke rehabilitation: A meta-analysis of the randomized controlled trials [J].
Glanz, M ;
Klawansky, S ;
Stason, W ;
Berkey, C ;
Chalmers, TC .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1996, 77 (06) :549-553
[10]  
Haugland M. K., 1995, IEEE Transactions on Rehabilitation Engineering, V3, P307, DOI 10.1109/86.481970