Penicillin enzyme biosensors based on pH membrane electrodes

被引:24
作者
Koncki, R [1 ]
Leszczynska, E [1 ]
机构
[1] UNIV WARSAW,DEPT CHEM,PL-02093 WARSAW,POLAND
关键词
potentiometry; biosensors; enzymatic methods; penicillinase;
D O I
10.1016/0003-2670(95)00547-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several penicillin biosensors obtained by covalent binding of penicillinase directly to the surface of pH detectors are presented. Two types of pH electrodes were used: membranes with tridodecylamine, as hydrogen ionophore, incorporated in carboxylated polyvinyl chloride, and membranes made of aminated polyvinyl chloride without any ionophore. Short response time and high stability characterize all described biosensors. The effects of several parameters on the shape of the calibration curves of the biosensors are discussed.
引用
收藏
页码:27 / 34
页数:8
相关论文
共 30 条
[1]   ENZYME SENSORS BASED ON COATED-WIRE ELECTRODE - USE OF CARBOXYL-SUBSTITUTED POLYVINYL-CHLORIDE) AS A SUPPORT FOR IMMOBILIZING PENICILLINASE [J].
ANZAI, J ;
SHIMADA, M ;
OSA, T ;
CHEN, C .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1987, 60 (11) :4133-4137
[2]  
ANZAI J, 1986, CHEM PHARM BULL, V34, P3522
[3]   PENICILLIN SENSORS BASED ON AN ION-SENSITIVE FIELD-EFFECT TRANSISTOR COATED WITH STEARIC-ACID LANGMUIR-BLODGETT MEMBRANE [J].
ANZAI, J ;
HASHIMOTO, J ;
OSA, T ;
MATSUO, T .
ANALYTICAL SCIENCES, 1988, 4 (03) :247-250
[4]  
ANZAI J, 1987, CHEM PHARM BULL, V35, P4568
[5]   DEVELOPMENT AND APPLICATION OF A NEW ENZYME SENSOR TYPE BASED ON THE EIS-CAPACITANCE STRUCTURE FOR BIOPROCESS CONTROL [J].
BEYER, M ;
MENZEL, C ;
QUACK, R ;
SCHEPER, T ;
SCHUGERL, K ;
TREICHEL, W ;
VOIGT, H ;
ULLRICH, M ;
FERRETTI, R .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (01) :17-21
[6]   FIELD-EFFECT TRANSISTOR SENSITIVE TO PENICILLIN [J].
CARAS, S ;
JANATA, J .
ANALYTICAL CHEMISTRY, 1980, 52 (12) :1935-1937
[7]   ONLINE MONITORING OF PENICILLIN-V DURING PENICILLIN FERMENTATIONS - A COMPARISON OF 2 DIFFERENT METHODS BASED ON FLOW-INJECTION ANALYSIS [J].
CARLSEN, M ;
JOHANSEN, C ;
MIN, RW ;
NIELSEN, J ;
MEIER, H ;
LANTREIBECQ, F .
ANALYTICA CHIMICA ACTA, 1993, 279 (01) :51-58
[8]  
CHEN CW, 1988, CHEM PHARM BULL, V36, P3671
[9]   CARBOXYLATED POLY(VINYL CHLORIDE) AS A SUBSTRATE FOR ION SENSORS - EFFECTS OF NATIVE ION-EXCHANGE ON RESPONSES [J].
COSOFRET, VV ;
BUCK, RP ;
ERDOSY, M .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3592-3599
[10]   ELECTROANALYTICAL AND BIOCOMPATIBILITY STUDIES ON CARBOXYLATED POLY(VINYL CHLORIDE) MEMBRANES FOR MICROFABRICATED ARRAY SENSORS [J].
COSOFRET, VV ;
ERDOSY, M ;
BUCK, RP ;
KAO, WJ ;
ANDERSON, JM ;
LINDNER, E ;
NEUMAN, MR .
ANALYST, 1994, 119 (11) :2283-2292