Determination of benzoic acid and sorbic acid in food products using electrokinetic flow analysis-ion pair solid phase extraction-capillary zone electrophoresis

被引:50
作者
Han, Fang [1 ]
He, You-Zhao [1 ]
Li, Lian [1 ]
Fu, Guo-Ni [1 ]
Xie, Hai-Yang [1 ]
Gan, Wu-Er [1 ]
机构
[1] Univ Sci & Technol China, Dept Chem, Hefei 230026, Peoples R China
基金
中国国家自然科学基金;
关键词
electrokinetic flow analysis; capillary zone electrophoresis; ion pair solid phase extraction; preservatives;
D O I
10.1016/j.aca.2008.04.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrokinetic flow analysis system (EFA), consisting of one electroosmotic pump, five solenoid valves and one on-line homemade solid phase extraction (SPE) unit, combined with capillary zone electrophoresis (CZE) was proposed to determine benzoic acid and sorbic acid in food products. Tetrabutylammonium bromide (TBAB) was adopted as an ion pair reagent to improve the retention of the preservatives on C-8-bonded silica sorbent, which was also used to remove sample matrices. By using the SPE unit, the EFA-SPE-CZE system was able to perform the SPE operation and CZE separation simultaneously. With a modified interface of EFA and CZE, the buffer consumption was reduced to 130 mu L for each running. The preservatives were separated and determined under optimized conditions with p-hydroxybenzoic acid as an internal standard. The relative standard deviation (R.S.D.) of peak area for each analyte was less than 3.1% (n=5) and the limits of detection (LODs) ranged from 10 to 20ngmL(-1) (K=3, n=11). Crown Copyright (C) 2008 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:79 / 85
页数:7
相关论文
共 44 条
[1]   On-line ion-exchange preconcentration in a flow injection system coupled to capillary electrophoresis for the direct determination of UV absorbing anions [J].
Arce, L ;
Kuban, P ;
Ríos, A ;
Valcárcel, M ;
Karlberg, B .
ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) :39-44
[2]   Validation of a micellar electrokinetic capillary chromatography method for the determination of imidurea, methyl and propylparabens in a pharmaceutical ointment [J].
Baalbaki, B ;
Blanchin, MD ;
Fabre, H .
ANALYTICA CHIMICA ACTA, 2002, 463 (01) :15-20
[3]  
Boyce MC, 2001, ELECTROPHORESIS, V22, P1447, DOI 10.1002/1522-2683(200105)22:8&lt
[4]  
1447::AID-ELPS1447&gt
[5]  
3.0.CO
[6]  
2-#
[7]   Combination of flow injection with capillary electrophoresis. Part 3. On-line sorption column preconcentration capillary electrophoresis system [J].
Chen, HW ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 1997, 355 (2-3) :135-143
[8]   Underarm cosmetics and breast cancer [J].
Darbre, PD .
JOURNAL OF APPLIED TOXICOLOGY, 2003, 23 (02) :89-95
[9]   Reversed-phase electrochromatography with a monolithic microcolumn prepared in a 2.2-mm-inner diameter fused-silica tube [J].
Deng, N ;
He, YZ ;
Wang, L ;
Wang, XK ;
Su, QD .
ANALYTICAL CHEMISTRY, 2005, 77 (17) :5622-5627
[10]   Sequential injection sample introduction microfluidic-chip based capillary electrophoresis system [J].
Fang, Q ;
Wang, FR ;
Wang, SL ;
Liu, SS ;
Xu, SK ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) :27-37