Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty

被引:217
作者
Belkoff, SM [1 ]
Molloy, S [1 ]
机构
[1] Johns Hopkins Univ, Johns Hopkins Bayview Med Ctr, Dept Orthopaed Surg, Orthopaed Instrumentat Lab, Baltimore, MD USA
关键词
exothermic vertebroplasty; temperature measurement; polymerization; osteoporosis; thermal necrosis;
D O I
10.1097/00007632-200307150-00015
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Ex vivo biomechanical study using osteoporotic cadaveric vertebral bodies. Objective. To measure internal vertebral body temperature during polymerization of cements used for vertebroplasty. Summary of Background Data. Previous ex vivo studies have shown that temperature increase during cement polymerization were unlikely to cause thermal necrosis. Methods. Twenty-four osteoporotic vertebral bodies were instrumented with thermocouples and injected with one of two cement volumes (6 or 10 mL) of one of two cements (Simplex P or modified Simplex P, Stryker-Howmedica-Osteonics, Kalamazoo, MI) Vertebral bodies were placed in a bath (37C) and temperatures were measured for 15 minutes from the time the cement was initially mixed. Results. In the vertebral bodies, peak temperatures at the anterior cortex ranged from 44C to 113C, those in the center ranged from 49C to 112C, and those at the spinal canal ranged from 39C to 57C. Dwell times at temperatures above 50C at the anterior cortex ranged from 0 to 5.5 minutes, those in the center ranged from 0 to 8 minutes, and those at the spinal canal ranged from 0 to 2.5 minutes. Conclusion. Internal temperature elevation measured during cement polymerization was substantially higher than previously reported and may be sufficiently high to pose a risk of thermal necrosis.
引用
收藏
页码:1555 / 1559
页数:5
相关论文
共 23 条
[1]   Percutaneous vertebroplasty for pain relief and spinal stabilization [J].
Barr, JD ;
Barr, MS ;
Lemley, TJ ;
McCann, RM .
SPINE, 2000, 25 (08) :923-928
[2]  
Bascoulergue Y, 1988, RADIOLOGY, V169, P372
[3]   The biomechanics of vertebroplasty - The effect of cement volume on mechanical behavior [J].
Belkoff, SM ;
Mathis, JM ;
Jasper, LE ;
Deramond, H .
SPINE, 2001, 26 (14) :1537-1541
[4]   An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty [J].
Belkoff, SM ;
Mathis, JM ;
Jasper, LE ;
Deramond, H .
SPINE, 2001, 26 (14) :1542-1546
[5]   Biomechanical evaluation of a new bone cement for use in vertebroplasty [J].
Belkoff, SM ;
Mathis, JM ;
Erbe, EM ;
Fenton, DC .
SPINE, 2000, 25 (09) :1061-1064
[6]   Future directions - Augmentation of osteoporotic vertebral bodies [J].
Bostrom, MPG ;
Lane, JM .
SPINE, 1997, 22 (24) :38S-42S
[7]   ACRYLIC PERCUTANEOUS VERTEBROPLASTY [J].
CHIRAS, J ;
SOLAMARTINEZ, MT ;
WEILL, A ;
ROSE, M ;
COGNARD, C ;
MARTINDUVERNEUIL, N .
REVUE DE MEDECINE INTERNE, 1995, 16 (11) :854-859
[8]  
Cortet B, 1999, J RHEUMATOL, V26, P2222
[9]   Percutaneous vertebroplasty: State of the art [J].
Cotten, A ;
Boutry, N ;
Cortet, B ;
Assaker, R ;
Demondion, X ;
Leblond, D ;
Chastanet, P ;
Duquesnoy, B ;
Deramond, H .
RADIOGRAPHICS, 1998, 18 (02) :311-320
[10]   Percutaneous vertebroplasty for osteolytic metastases and myeloma: Effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up [J].
Cotten, A ;
Dewatre, F ;
Cortet, B ;
Assaker, R ;
Leblond, D ;
Duquesnoy, B ;
Chastanet, P ;
Clarisse, J .
RADIOLOGY, 1996, 200 (02) :525-530