Recombinant growth hormone delivery systems based on vinylpyrrolidone-hydroxyethyl methacrylate copolymer matrices:: Monitoring optimization by capillary zone electrophoresis

被引:13
作者
Cifuentes, A
Diez-Masa, JC
Montenegro, C
Rebuelta, M
Gallardo, A
Elvira, C
San Román, J [1 ]
机构
[1] CSIC, Inst Sci & Technol Polymers, Madrid, Spain
[2] CSIC, Inst Organ Chem, E-28006 Madrid, Spain
[3] Univ Complutense, Fac Farm, Dept Farmacol, E-28040 Madrid, Spain
关键词
growth hormone; controlled release; vinylpyrrolidone-hydroxyethyl methacrylate; copolymers; capillary zone electrophoresis;
D O I
10.1163/156856200744156
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Experimental conditions for the fabrication of two new polymeric devices (i.e. films and slabs) useful for the controlled release of recombinant growth hormone (GH) are given. The release rate is controlled by the resorption profile of the vinylpyrrolidone-hydroxyethyl methacrylate (VP-HEMA) tested systems which is related to the copolymer composition. The suitability of capillary electrophoresis (CE) for following the complete preparation of the different VP-HEMA devices is shown. Moreover, CE allows simultaneous monitoring of the controlled release of GH and dissolved polymer during in vitro experiments. From these results, guidelines are given for the fabrication of polymeric devices containing protein as active drug as well as for the correct selection of conditions during in vitro experiments.
引用
收藏
页码:993 / 1005
页数:13
相关论文
共 17 条
[1]  
AKASHI M, 1990, ADV POLYM SCI, V97, P107
[2]  
Beale SC, 1998, ANAL CHEM, V70, p279R
[3]   Controlled release of cytarabine from poly(2-hydroxyethyl methacrylate-co-N-vinyl-2-pyrrolidone) hydrogels [J].
Blanco, MD ;
Trigo, RM ;
Garcia, O ;
Teijon, JM .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1997, 8 (09) :709-719
[4]   OPTIMUM CONDITIONS FOR PREPARATIVE OPERATION OF CAPILLARY ZONE ELECTROPHORESIS [J].
CIFUENTES, A ;
XU, X ;
KOK, WT ;
POPPE, H .
JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) :141-156
[5]   CAPILLARY ELECTROPHORESIS USING AIR AND HELIUM AS COOLING FLUIDS [J].
CIFUENTES, A ;
KOK, WT ;
POPPE, H .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1995, 7 (04) :365-374
[6]   ANALYSIS OF RECOMBINANT HUMAN GROWTH-HORMONE AND ITS RELATED IMPURITIES BY CAPILLARY ELECTROPHORESIS [J].
DUPIN, P ;
GALINOU, F ;
BAYOL, A .
JOURNAL OF CHROMATOGRAPHY A, 1995, 707 (02) :396-400
[7]   INTRINSIC VISCOSITY-MOLECULAR WEIGHT RELATIONSHIPS FOR POLY(2-HYDROXYETHYL METHACRYLATE) [J].
FORT, RJ ;
POLYZOIDIS, TM .
EUROPEAN POLYMER JOURNAL, 1976, 12 (09) :685-689
[8]   Micellar electrokinetic chromatography applied to copolymer systems with heterogeneous distribution [J].
Gallardo, A ;
Lemus, AR ;
Román, JS ;
Cifuentes, A ;
Díez-Masa, JC .
MACROMOLECULES, 1999, 32 (03) :610-617
[9]   Controlled release of cyclosporine from VP-HEMA copolymer systems of adjustable resorption monitorized by MEKC [J].
Gallardo, A ;
Fernández, F ;
Bermejo, P ;
Rebuelta, M ;
Cifuentes, A ;
Díez-Masa, JC ;
San Román, J .
BIOMATERIALS, 2000, 21 (09) :915-921
[10]  
GALLARDO A, UNPUB J CONTROL REL