Nonfluoroscopic localization of intracardiac electrode-catheters combined with noncontact electrical-anatomical imaging

被引:1
作者
Rao, LY [1 ]
Ding, CX [1 ]
Khoury, DS [1 ]
机构
[1] Baylor Coll Med, Dept Med, Ctr Expt Cardiac Electrophysiol, Cardiol Sect, Houston, TX 77030 USA
关键词
ablation; cardiac mapping; imaging/ultrasound;
D O I
10.1007/s10439-004-7818-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We recently combined noncontact mapping and intracardiac echocardiography (ICE) in a single catheter-system that permitted 3D electrical-anatomical imaging of the heart. The objective of the present study was to develop a nonfluoroscopic method to localize standard, navigational electrode-catheters, which also operated in conjunction with noncontact electrical-anatomical imaging. Accordingly, electrode-catheters were fixed at the endocardium in the LV of three dogs and in the RA of two other dogs. A catheter-system was placed inside the heart cavity, and consisted of a 9-F sheath carrying a coaxial noncontact 64-electrode lumen-probe on the outside (diameter = 7 mm), and a central ICE catheter on the inside (9 MHz). To reconstruct the endocardial anatomy, the ICE catheter was pulled back inside the sheath and multiple 2D tomographic images were acquired. The noncontact probe was then advanced over the sheath and into the heart cavity. Current pulses were injected into the endocardial contact electrodes and all probe electrodes sensed corresponding potentials. Measured probe potentials localized the endocardial electrodes based on the least squares numeric method, and was verified by ICE. We found that the 3D endocardial geometry reconstructed by ICE depicted important anatomical details. All endocardial electrodes were identified by ICE and were correctly matched with corresponding endocardial anatomy. The difference in computed electrode locations compared to ICE was 5.4 +/- 2.4 mm (n = 10). In conclusion, nonfluoroscopic localization of standard navigational electrode-catheters within true and detailed 3D images of cardiac anatomy is feasible. Integrating this approach with noncontact electrical-anatomical imaging could facilitate diagnosing arrhythmias and advancing their therapy.
引用
收藏
页码:1654 / 1661
页数:8
相关论文
共 17 条
[11]  
Khoury DS, 1998, CIRCULATION, V97, P399
[12]   INTRACAVITARY MAPPING - AN IMPROVED METHOD FOR LOCATING THE SITE OF ORIGIN OF ECTOPIC VENTRICULAR BEATS BY MEANS OF A MATHEMATICAL-MODEL [J].
MACCHI, E ;
ARISI, G ;
TACCARDI, B .
PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, :187-188
[13]   Catheter ablation of supraventricular arrhythmias: State of the art [J].
Morady, F .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (01) :124-139
[14]   Novel noncontact catheter system for endocardial electrical and anatomical imaging [J].
Rao, LY ;
He, RJ ;
Ding, CX ;
Khoury, DS .
ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (04) :573-584
[15]   Intracardiac echocardiography (9 MHz) in humans: Methods, imaging views and clinical utility [J].
Ren, JF ;
Schwartzman, D ;
Callans, DJ ;
Brode, SE ;
Gottlieb, CD ;
Marchlinski, FE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (07) :1077-1086
[16]   Simultaneous endocardial mapping in the human left ventricle using a noncontact catheter - Comparison of contact and reconstructed electrograms during sinus rhythm [J].
Schilling, RJ ;
Peters, NS ;
Davies, W .
CIRCULATION, 1998, 98 (09) :887-898
[17]   LocaLisa - New technique for real-time 3-dimensional localization of regular intracardiac electrodes [J].
Wittkampf, FHM ;
Wever, EFD ;
Derksen, R ;
Wilde, AAM ;
Ramanna, H ;
Hauer, RNW ;
de Medina, EOR .
CIRCULATION, 1999, 99 (10) :1312-1317