Recording of short-term finger blood pressure changes induced by an arterial occlusive thigh cuff:: Comparison between the modified oscillometric and Finapres techniques

被引:7
作者
Raamat, R
Jagomägi, K
Talts, J
Toska, K
Walloc, L
机构
[1] Univ Tartu, Dept Physiol, EE-51014 Tartu, Estonia
[2] Univ Oslo, Inst Basic Med Sci, Dept Physiol, N-0317 Oslo, Norway
关键词
non-invasive blood pressure; Finapres; oscillometric finger mean blood pressure; thigh cuff;
D O I
10.1088/0967-3334/22/2/402
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Blood pressure recordings obtained by the volume clamp method (Finapres monitor; Ohmeda, USA) were compared with measurements by using a novel modification of the oscillometric method (UT9201 beat-to-brat monitor, University of Tartu, Estonia). Step changes in total peripheral resistance were introduced in 11 healthy volunteers by rapid inflation to the suprasystolic pressure of bilateral thigh cuffs during a rhythmical exercise wi th the quadriceps muscles and simultaneously performed handgrip compression. The provoked short-term changes in mean arterial pressure (MAP) were similarly tracked by both devices, The agreement between the methods was better for MAP rise than drop. The group-averaged difference UT9201 minus Finapres did not exceed 1.2 mmHg (NS, p = 0.46) after cuff successive inflation but yielded 3.8 mmHg (significant, p < 0.05) after cuff successive deflation.
引用
收藏
页码:N13 / N20
页数:8
相关论文
共 15 条
[1]   THE RELIABILITY OF NONINVASIVE CONTINUOUS FINGER BLOOD-PRESSURE MEASUREMENT IN PATIENTS WITH BOTH HYPERTENSION AND VASCULAR-DISEASE [J].
BOS, WJW ;
IMHOLZ, BPM ;
VANGOUDOEVER, J ;
WESSELING, KH ;
VANMONTFRANS, GA .
AMERICAN JOURNAL OF HYPERTENSION, 1992, 5 (08) :529-535
[2]  
Imholz B P, 1991, Clin Auton Res, V1, P43, DOI 10.1007/BF01826057
[3]   Fifteen years experience with finger arterial pressure monitoring: assessment of the technology [J].
Imholz, BPM ;
Wieling, W ;
van Montfrans, GA ;
Wesseling, KH .
CARDIOVASCULAR RESEARCH, 1998, 38 (03) :605-616
[4]   NONINVASIVE CONTINUOUS FINGER BLOOD-PRESSURE MEASUREMENT DURING ORTHOSTATIC STRESS COMPARED TO INTRAARTERIAL PRESSURE [J].
IMHOLZ, BPM ;
SETTELS, JJ ;
VANDERMEIRACKER, AH ;
WESSELING, KH ;
WIELING, W .
CARDIOVASCULAR RESEARCH, 1990, 24 (03) :214-221
[5]   Continuous non-invasive measurement of mean blood pressure in fingers by volume-clamp and differential oscillometric method [J].
Jagomagi, K ;
Talts, J ;
Raamat, R ;
Lansimies, E .
CLINICAL PHYSIOLOGY, 1996, 16 (05) :551-560
[6]   CONTINUOUS, NONINVASIVE VOLUME-CLAMP BLOOD-PRESSURE - DETERMINANTS OF PERFORMANCE [J].
LAL, SKL ;
MIHAILIDOU, AS ;
CEJNAR, M ;
HENDERSON, RJ ;
JONES, M ;
HUNYOR, SN .
JOURNAL OF HYPERTENSION, 1993, 11 (12) :1413-1422
[7]   Why use Finapres or Portapres rather than intraarterial or intermittent non-invasive techniques of blood pressure measurement? [J].
Langewouters, GJ ;
Settels, JJ ;
Roelandt, R ;
Wesseling, KH .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1998, 22 (01) :37-43
[8]   Assessment of the thigh cuff technique for measurement of dynamic cerebral autoregulation [J].
Mahony, PJ ;
Panerai, RB ;
Deverson, ST ;
Hayes, PD ;
Evans, DH .
STROKE, 2000, 31 (02) :476-480
[9]  
PENAZ J, 1973, DIG 10 INT C MED BIO, P104
[10]  
Raamat R, 2000, J MED ENG TECHNOL, V24, P95, DOI 10.1080/03091900050135004