Amperometric immunosensing using microperoxidase MP-11 antibody conjugates

被引:34
作者
Padeste, C [1 ]
Grubelnik, A [1 ]
Tiefenauer, L [1 ]
机构
[1] Paul Scherrer Inst, Lab Micro & Nanostruct, CH-5232 Villigen, Switzerland
关键词
immunosensor; microperoxidase; electrocatalytic reduction;
D O I
10.1016/S0003-2670(98)00466-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical immunosensing requires labeling because most antigen and antibody species are electrochemically inert. The use of microperoxidase as the label is most promising due to its electrocatalytic activity, which is utilized for signal amplification. A method for coupling the microperoxidase MP-11 to antibody molecules has been developed. The electrocatalytic effect of the conjugate when immobilized on gold electrodes has been demonstrated. Using the streptavidin-biotin system the antigen estradiol was immobilized on gold. Recognition of labeled antibody could be detected electrochemically. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:167 / 176
页数:10
相关论文
共 28 条
[1]   Photochemically-activated electrodes: application in design of reversible immunosensors and antibody patterned interfaces [J].
Blonder, R ;
BenDov, I ;
Dagan, A ;
Willner, I ;
Zisman, E .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (07) :627-644
[2]   Development of amperometric and microgravimetric immunosensors and reversible immunosensors using antigen and photoisomerizable antigen monolayer electrodes [J].
Blonder, R ;
Levi, S ;
Tao, GL ;
BenDov, I ;
Willner, I .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (43) :10467-10478
[3]   ANTIGEN-IMMOBILIZED VERSUS ANTIBODY-IMMOBILIZED ELISA PROCEDURES BASED ON A BIOTINYL-ESTRADIOL CONJUGATE [J].
BODMER, DM ;
TIEFENAUER, LX ;
ANDRES, RY .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 1989, 33 (06) :1161-1166
[4]   BIOCHEMICAL ASPECTS OF BIOSENSORS [J].
BYFIELD, MP ;
ABUKNESHA, RA .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (4-5) :373-400
[5]  
Dempsey E, 1997, ANAL CHIM ACTA, V346, P341
[6]   SEPARATION-FREE SANDWICH ENZYME IMMUNOASSAYS USING MICROPOROUS GOLD ELECTRODES AND SELF-ASSEMBLED MONOLAYER IMMOBILIZED CAPTURE ANTIBODIES [J].
DUAN, CM ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1369-1377
[7]   Flow-through amperometric immunosensor: Fast 'sandwich' scheme immunoassay [J].
Ghindilis, AL ;
Krishnan, R ;
Atanasov, P ;
Wilkins, E .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (05) :415-423
[8]  
Green N M, 1975, Adv Protein Chem, V29, P85, DOI 10.1016/S0065-3233(08)60411-8
[9]   Amperometric amplification of antigen-antibody association at monolayer interfaces: Design of immunosensor electrodes [J].
Katz, E ;
Willner, I .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 418 (1-2) :67-72
[10]   Electrical contact of redox enzymes with electrodes: Novel approaches for amperometric biosensors [J].
Katz, E ;
HelegShabtai, V ;
Willner, B ;
Willner, I ;
Buckmann, AF .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1997, 42 (01) :95-104