Automated detection of microcalcification clusters for digital breast tomosynthesis using projection data only: A preliminary study

被引:42
作者
Reiser, I. [1 ]
Nishikawa, R. M. [1 ]
Edwards, A. V. [1 ]
Kopans, D. B. [2 ]
Schmidt, R. A. [1 ]
Papaioannou, J. [1 ]
Moore, R. H. [2 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Massachusetts Gen Hosp, Boston, MA 02214 USA
关键词
breast imaging; tomosynthesis; computer-aided detection; microcalcification cluster;
D O I
10.1118/1.2885366
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Digital breast tomosynthesis (DBT) is a promising modality for breast imaging in which an anisotropic volume image of the breast is obtained. We present an algorithm for computerized detection of microcalcification clusters (MCCs) for DBT. This algorithm operates on the projection views only. Therefore it does not depend on reconstruction, and is computationally efficient. The algorithm was developed using a database of 30 image sets with microcalcifications, and a control group of 30 image sets without visible findings. The patient data were acquired on the first DBT prototype at Massachusetts General Hospital. Algorithm sensitivity was estimated to be 0.86 at 1.3 false positive clusters, which is below that of current MCC detection algorithms for full-field digital mammography. Because of the small number of patient cases, algorithm parameters were not optimized and one linear classifier was used. An actual limitation of our approach may be that the signal-to-noise ratio in the projection images is too low for microcalcification detection. Furthermore, the database consisted of predominantly small MCC. This may be related to the image quality obtained with this first prototype. (c) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:1486 / 1493
页数:8
相关论文
共 36 条
  • [1] [Anonymous], P SPIE
  • [2] Anisotropic imaging performance in indirect x-ray imaging detectors
    Badano, Aldo
    Kyprianou, Iacovos S.
    Sempau, Josep
    [J]. MEDICAL PHYSICS, 2006, 33 (08) : 2698 - 2713
  • [3] Digital breast tomosynthesis using an amorphous selenium flat panel detector
    Bissonnette, M
    Hansroul, M
    Masson, E
    Savard, S
    Cadieux, S
    Warmoes, P
    Gravel, D
    Agopyan, J
    Polischuk, B
    Haerer, W
    Mertelmeier, T
    Lo, JY
    Chen, Y
    Dobbins, JT
    Jesneck, JL
    Singh, S
    [J]. Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 529 - 540
  • [4] Estimation of the noisy component of anatomical backgrounds
    Bochud, FO
    Valley, JF
    Verdun, FR
    Hessler, C
    Schnyder, P
    [J]. MEDICAL PHYSICS, 1999, 26 (07) : 1365 - 1370
  • [5] Human observer detection experiments with mammograms and power-law noise
    Burgess, AE
    Jacobson, FL
    Judy, PF
    [J]. MEDICAL PHYSICS, 2001, 28 (04) : 419 - 437
  • [6] IMAGE FEATURE ANALYSIS AND COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY .1. AUTOMATED DETECTION OF MICROCALCIFICATIONS IN MAMMOGRAPHY
    CHAN, HP
    DOI, K
    GALHOTRA, S
    VYBORNY, CJ
    MACMAHON, H
    JOKICH, PM
    [J]. MEDICAL PHYSICS, 1987, 14 (04) : 538 - 548
  • [7] Digital x-ray tomosynthesis: current state of the art and clinical potential
    Dobbins, JT
    Godfrey, DJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19) : R65 - R106
  • [8] Screening mammography with computer-aided detection: Prospective study of 12,860 patients in a community breast center
    Freer, TW
    Ulissey, MJ
    [J]. RADIOLOGY, 2001, 220 (03) : 781 - 786
  • [9] Computer aided detection of clusters of microcalcifications on full field digital mammograms
    Ge, Jun
    Sahiner, Berkman
    Hadjiiski, Lubomir M.
    Chan, Heang-Ping
    Wei, Jun
    Helvie, Mark A.
    Zhou, Chuan
    [J]. MEDICAL PHYSICS, 2006, 33 (08) : 2975 - 2988
  • [10] Physical characteristics of GE senographe essential and DS digital mammography detectors
    Ghetti, Caterina
    Borrini, Adriano
    Ortenzia, Ornella
    Rossi, Raffaella
    Ordonez, Pedro L.
    [J]. MEDICAL PHYSICS, 2008, 35 (02) : 456 - 463