Diagnostics on Z (invited)

被引:63
作者
Nash, TJ
Derzon, MS
Chandler, GA
Fehl, DL
Leeper, RJ
Porter, JL
Spielman, RB
Ruiz, C
Cooper, G
McGurn, J
Hurst, M
Jobe, D
Torres, J
Seaman, J
Struve, K
Lazier, S
Gilliland, T
Ruggles, LA
Simpson, WA
Adams, R
Seaman, JA
Wenger, D
Nielsen, D
Riley, P
French, R
Stygar, B
Wagoner, T
Sanford, TWL
Mock, R
Asay, J
Hall, C
Knudson, M
Armijo, J
McKenney, J
Hawn, R
Schroen-Carey, D
Hebron, D
Cutler, T
Dropinski, S
Deeney, C
LePell, PD
Coverdale, CA
Douglas, M
Cuneo, M
Hanson, D
Bailey, JE
Lake, P
Carlson, A
Wakefield, C
Mills, J
机构
[1] Sandia Natl Labs, Albuquerque, NM 87185 USA
[2] Univ Calif Los Alamos Natl Lab, Los Alamos, NM 87545 USA
关键词
D O I
10.1063/1.1322618
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The 100 ns, 20 MA pinch-driver Z is surrounded by an extensive set of diagnostics. There are nine radial lines of sight set at 12 degrees above horizontal and each of these may be equipped with up to five diagnostic ports. Instruments routinely fielded viewing the pinch from the side with these ports include x-ray diode arrays, photoconducting detector arrays, bolometers, transmission grating spectrometers, time-resolved x-ray pinhole cameras, x-ray crystal spectrometers, calorimeters, silicon photodiodes, and neutron detectors. A diagnostic package fielded on axis for viewing internal pinch radiation consists of nine lines of sight. This package accommodates virtually the same diagnostics as the radial ports. Other diagnostics not fielded on the axial or radial ports include current B-dot monitors, filtered x-ray scintillators coupled by fiber optics to streak cameras, streaked visible spectroscopy, velocity interferometric system for any reflector, bremsstrahlung cameras, and active shock breakout measurement of hohlraum temperature. The data acquisition system is capable of recording up to 500 channels and the data from each shot is available on the Internet. A major new diagnostic presently under construction is the BEAMLET backlighter. We will briefly describe each of these diagnostics and present some of the highest-quality data from them. (C) 2001 American Institute of Physics.
引用
收藏
页码:1167 / 1172
页数:6
相关论文
共 25 条
[1]  
[Anonymous], REV SCI INSTRUM
[2]   High-accuracy time- and space-resolved Stark shift measurements (invited) [J].
Bailey, JE ;
Adams, R ;
Carlson, AL ;
Ching, CH ;
Filuk, AB ;
Lake, P .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01) :1009-1014
[3]  
CARD JA, 1998, UNPUB 3 ANN INT C SO
[4]   Calibration of a direct nuclear activation diagnostic which uses boron nitride to measure energetic deuterium ions [J].
Chambers, GD ;
Cooper, GW ;
Savage, ME ;
Ruiz, CL ;
Schmidlapp, FA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01) :1205-1208
[5]   Filtered x-ray diode diagnostics fielded on the Z accelerator for source power measurements [J].
Chandler, GA ;
Deeney, C ;
Cuneo, M ;
Fehl, DL ;
McGurn, JS ;
Spielman, RB ;
Torres, JA ;
McKenney, JL ;
Mills, J ;
Struve, KW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01) :561-565
[6]   Measurement and simulation of apertures on Z hohlraums [J].
Chrien, RE ;
Matuska, W ;
Idzorek, G ;
Swenson, FJ ;
Peterson, DL ;
Wilde, BH ;
Porter, JL ;
Breeze, SP ;
Ruggles, LE ;
Simpson, WW ;
Vargas, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01) :557-560
[7]   Implications of high-energy photons and electrons on target preheat at the Sandia "Z" facility [J].
Derzon, M ;
Nash, T ;
Chandler, G ;
Cooper, G ;
Fehl, D ;
Hall, C ;
Lash, J ;
Leeper, R ;
McGuire, E ;
Mock, R ;
Olsen, R ;
Olson, C ;
Rochau, GE ;
Rochau, GA ;
Ruiz, C ;
Seamen, J ;
Slutz, S ;
Stygar, W ;
Sweeney, MA ;
Lazier, S ;
Droemer, D ;
Helvin, T ;
Starbird, R .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01) :566-568
[8]   Absolute, soft x-ray calorimetry on the Z facility at Sandia National Laboratories (invited) [J].
Fehl, DL ;
Muron, DJ ;
Leeper, RJ ;
Chandler, GA ;
Deeney, C ;
Stygar, WA ;
Spielman, RB .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01) :270-275
[9]   Fielding of the on-axis diagnostic package at Z [J].
Hurst, MJ ;
Nash, TJ ;
Derzon, M ;
Kellogg, JW ;
Torres, J ;
McGurn, J ;
Seaman, J ;
Jobe, D ;
Lazier, SE .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01) :468-470
[10]  
LASH JS, 1999, UNPUB P 1 IFSA C BOR