Towards a microchip-based chromatographic platform. Part 2: Sol-gel phases modified with polyelectrolyte multilayers for capillary electrochromatography

被引:21
作者
Breadmore, MC
Shrinivasan, S
Karlinsey, J
Ferrance, JP
Norris, PM
Landers, JP
机构
[1] Univ Virginia, Dept Chem, Charlottesville, VA 22904 USA
[2] Univ Virginia, Dept Mech & Aerosp Engn, Charlottesville, VA 22904 USA
[3] Univ Virginia, Dept Pathol, Hlth Sci Ctr, Charlottesville, VA 22903 USA
关键词
capillary electrochromatography; miniaturization; polyelectrolyte multilayers; silica monolithic column; sol-gel phase;
D O I
10.1002/elps.200390162
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The potential for using polyelectrolyte multilayers (PEMs) to provide chromatographic functionality on continuous silica networks created from sol-gel chemistry has been evaluated by capillary electrochromatography (CEC). Construction of the PEM was achieved by flushing the column with polyelectrolytes of alternative charge, with variation of the properties of the exposed polyelectrolyte providing a unique means to vary the chromatographic surface. Variation of the exposed polyelectrolyte from poly(diallyldimethylammonium chloride) (PDDAC) to dextran sulfate (DS) allowed the direction of the electroosmotic flow (EOF) to be changed and also provided a means to vary the chromatographic capacity. Variation, of negative polymer from DS to poly(styrene sulfonate) (PSS) significantly altered the EOF and the migration of peptides, with both the reversed-phase and ion-exchange capacities increasing. An alternative method for changing the column capacity was to change the thickness of the PEM, which was evaluated by anion-exchange CEC. A 70-80% increase in retention was observed, for all anions without any increase in EOF suggesting significant penetration of the analytes through the PEM and interaction with buried charges within the PEM.
引用
收藏
页码:1261 / 1270
页数:10
相关论文
共 55 条
[1]   On capillary ion-exchange preconcentration of inorganic anions in open-tubular capillary electrochromatography with elution using transient-isotachophoretic gradients. 2. Characterization of the isotachophoretic gradient [J].
Breadmore, MC ;
Macka, M ;
Avdalovic, N ;
Haddad, PR .
ANALYTICAL CHEMISTRY, 2001, 73 (04) :820-828
[2]  
BREADMORE MC, 2003, IN PRESS ELECTROPHOR, V24
[3]   Chemically L-phenylalaninamide-modified monolithic silica column prepared by a sol-gel process far enantioseparation of dansyl amino acids by ligand exchange-capillary electrochromatography [J].
Chen, ZL ;
Hobo, T .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3348-3357
[4]   Utilization of the sol-gel technique for the development of novel stationary phases for capillary electrochromatography on a chip [J].
Constantin, S ;
Freitag, R ;
Solignac, D ;
Sayah, A ;
Gijs, MAM .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 78 (1-3) :267-272
[5]   Noncovalent polycationic coatings for capillaries in capillary electrophoresis of proteins [J].
Cordova, E ;
Gao, JM ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1997, 69 (07) :1370-1379
[6]   Fuzzy nanoassemblies: Toward layered polymeric multicomposites [J].
Decher, G .
SCIENCE, 1997, 277 (5330) :1232-1237
[7]   Separation of basic solutes by reversed-phase capillary electrochromatography [J].
Dittmann, MM ;
Masuch, K ;
Rozing, GP .
JOURNAL OF CHROMATOGRAPHY A, 2000, 887 (1-2) :209-221
[8]   Multiple membranes from "true" polyelectrolyte multilayers [J].
Dubas, ST ;
Farhat, TR ;
Schlenoff, JB .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (22) :5368-5369
[9]   Factors controlling the growth of polyelectrolyte multilayers [J].
Dubas, ST ;
Schlenoff, JB .
MACROMOLECULES, 1999, 32 (24) :8153-8160
[10]   Photopolymerized sol-gel monoliths for capillary electrochromatography [J].
Dulay, MT ;
Quirino, JP ;
Bennett, BD ;
Kato, M ;
Zare, RN .
ANALYTICAL CHEMISTRY, 2001, 73 (16) :3921-3926