Influence of simulator kinematics on the wear of metal-on-metal hip prostheses

被引:43
作者
Firkins, PJ
Tipper, JL
Ingham, E
Stone, MH
Farrar, R
Fisher, J [1 ]
机构
[1] Univ Leeds, Sch Mech Engn, Leeds LS2 9JT, W Yorkshire, England
[2] Univ Leeds, Div Microbiol, Leeds LS2 9JT, W Yorkshire, England
[3] Gen Infirm, Dept Orthopaed Surg, Leeds LS1 3EX, W Yorkshire, England
[4] DePuy Int Ltd, Leeds, W Yorkshire, England
关键词
hip prostheses; metal-on-metal; bearing; wear; debris; kinematics;
D O I
10.1243/0954411011533481
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
There is now considerable interest in metal-on-metal bearings for hip prostheses. Extremely low wear rates (0.1 mm(3)/10(6) cycles) have been reported in some simulator studies, while in vivo studies, although still very low, have shown wear rates of the order of 1 mm(3)/10(6) cycles. The aim of this study was to compare wear rates of metal-on-metal bearings in two hip simulators with different kinematic inputs. In the simulator with three independent input motions which produced an open elliptical wear path with a low level of eccentricity, the wear rates were very low as recorded previously in other simulators. In the simulator with two input motions which produced an open elliptical wear path with greater eccentricity the wear rate was at least ten times higher and closer to clinical values. The motion and kinematic conditions in the contact are critical determinants of wear in metal-on-metal bearings.
引用
收藏
页码:119 / 121
页数:3
相关论文
共 9 条
[1]
Amstutz H. C., 1996, CLIN ORTHOP S, V329, P11
[2]
A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates [J].
Barbour, PSM ;
Stone, MH ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H6) :455-467
[3]
CHAN FW, 1999, T ORTHOP RES SOC, V24, P310
[4]
A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements [J].
Goldsmith, AAJ ;
Dowson, D ;
Isaac, GH ;
Lancaster, JG .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H1) :39-47
[5]
IRKINS PJ, 1999, T ORTHOP RES SOC, V24, P49
[6]
MEDLEY JB, 1996, CLIN ORTHOP S, V329, P148
[7]
NEVELOS JE, 2000, T ORTHOP RES SOC, V25, P28
[8]
Paul JP., 1966, P I MECH ENG, V181, P8
[9]
Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements [J].
Tipper, JL ;
Firkins, PJ ;
Ingham, E ;
Fisher, J ;
Stone, MH ;
Farrar, R .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1999, 10 (06) :353-362