The effect on dose to computed tomography phantoms of varying the theoretical x-ray spectrum: A comparison of four diagnostic x-ray spectrum calculating codes

被引:23
作者
Caon, M [1 ]
Bibbo, G
Pattison, J
Bhat, M
机构
[1] Flinders Univ S Australia, Sch Nursing, Bedford Pk, SA 5042, Australia
[2] Univ S Australia, Sch Phys & Elect Syst Engn, The Levels, SA 5095, Australia
[3] Womens & Childrens Hosp, Div Med Imaging, Adelaide, SA 5006, Australia
关键词
diagnostic x-ray spectrum; theoretical x-ray spectrum;
D O I
10.1118/1.598281
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Theoretical x-ray spectra calculated by four different codes for the same tube parameters are compared by calculating and measuring doses to computed tomography (CT) body and head phantoms. The effect on the 120 kV spectrum, and hence on the calculated dose, of varying the anode angle, tube voltage, and total filtration of the x-ray tube is investigated. Codes used were those of Nowotny and Hofer (XCOMP), Boone, Iles, and Tucker et al. The code based on the work of Tucker et al. produced calculated doses noticeably lower than the other codes and compared best to the measured value. The variation in calculated dose between the Tucker code and the others is of the same order as the variation introduced by uncertainties in total filtration of about 20%, in peak tube voltage of +/- 4 kV, and in change of anode angle from 7 degrees to 13 degrees. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)00806-2].
引用
收藏
页码:1021 / 1027
页数:7
相关论文
共 23 条
[1]   CT DOSES IN CYLINDRICAL PHANTOMS [J].
ATHERTON, JV ;
HUDA, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (05) :891-911
[2]   Diagnostic x-ray spectra: A comparison of spectra generated by different computational methods with a measured spectrum [J].
Bhat, M ;
Pattison, J ;
Bibbo, G ;
Caon, M .
MEDICAL PHYSICS, 1998, 25 (01) :114-120
[3]   COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517
[4]  
BIRCH R, 1979, CATALOGUE SPECTRAL D
[5]   A COMPARISON OF SEMIEMPIRICAL MODELS FOR GENERATING TUNGSTEN TARGET X-RAY-SPECTRA [J].
BISSONNETTE, JP ;
SCHREINER, LJ .
MEDICAL PHYSICS, 1992, 19 (03) :579-582
[6]   THE 3 PARAMETER EQUIVALENT SPECTRA AS AN INDEX OF BEAM QUALITY [J].
BOONE, JM .
MEDICAL PHYSICS, 1988, 15 (03) :304-310
[7]   A comparison of radiation dose measured in CT dosimetry phantoms with calculations using EGS4 and voxel-based computational models [J].
Caon, M ;
Bibbo, G ;
Pattison, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (01) :219-229
[8]  
Caon M., 1996, Australasian Physical and Engineering Sciences in Medicine, V19, P201
[9]  
Cranley K, 1991, 64 IPSM
[10]  
Fewell T., 1981, HDB COMPUTED TOMOGRA