Use of a multileaf collimator as a dynamic missing-tissue compensator

被引:26
作者
Geis, P [1 ]
Boyer, AL [1 ]
Wells, NH [1 ]
机构
[1] UNIV TEXAS,MD ANDERSON CANC CTR,DEPT RADIAT PHYS,HOUSTON,TX 77030
关键词
compensating filters; beam modulation; multileaf collimators;
D O I
10.1118/1.597675
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A dynamic multileaf collimator (D-MLC) was used to investigate the feasibility of producing missing-tissue compensators. The modulation of the x-ray field in two dimensions produced by conventional physical compensators was mimicked by delivering a sequence of D-MLC-shaped subfields. A method is introduced to calculate monitor units (MU) for dynamically compensated fields that is analogous to and expands upon methods used for conventional compensating filter MU calculations. In this investigation, the tissue deficit at the surface of an anatomical phantom was measured using a Moire camera. The tissue deficit data were used to generate a series of D-MLC subfields that, delivered in sequence, provided the compensated treatment. Film was used to integrate the dose delivered to a specified depth of compensation. Isodose distributions were measured for uncompensated fields, fields compensated with a conventional lead or plastic filter, and fields compensated with the D-MLC. A comparison of the dose distributions shows the compensation achieved with the dynamic compensating filter is comparable to that achieved using conventional physical compensating filters. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:1199 / 1205
页数:7
相关论文
共 22 条
  • [1] BINDER W, 1977, STRAHLENTHER ONKOL, V153, P82
  • [2] BOGE RJ, 1974, RADIOLOGY, V111, P19
  • [3] X-RAY FIELD COMPENSATION WITH MULTILEAF COLLIMATORS
    BORTFELD, TR
    KAHLER, DL
    WALDRON, TJ
    BOYER, AL
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03): : 723 - 730
  • [4] COMPENSATING FILTERS FOR HIGH-ENERGY X-RAYS
    BOYER, AL
    [J]. MEDICAL PHYSICS, 1982, 9 (03) : 429 - 433
  • [5] SIMULATOR MOUNTED MOIRE TOPOGRAPHY CAMERA FOR CONSTRUCTING COMPENSATING FILTERS
    BOYER, AL
    GOITEIN, M
    [J]. MEDICAL PHYSICS, 1980, 7 (01) : 19 - 26
  • [6] BOYER AL, 1983, ADV RAD THERAPY TREA, P185
  • [7] OPTIMIZATION OF STATIONARY AND MOVING BEAM RADIATION-THERAPY TECHNIQUES
    BRAHME, A
    [J]. RADIOTHERAPY AND ONCOLOGY, 1988, 12 (02) : 129 - 140
  • [8] THE GENERATION OF INTENSITY-MODULATED FIELDS FOR CONFORMAL RADIOTHERAPY BY DYNAMIC COLLIMATION
    CONVERY, DJ
    ROSENBLOOM, ME
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (06) : 1359 - 1374
  • [9] SEMIAUTOMATIC CUTTER FOR COMPENSATING FILTERS
    CUNNINGHAM, JR
    WRIGHT, DJ
    WEBB, HP
    RAWLINSON, JA
    LEUNG, PMK
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1976, 1 (3-4): : 355 - 360
  • [10] A COMPENSATOR FOR VARIATIONS IN TISSUE THICKNESS FOR HIGH ENERGY BEAMS
    ELLIS, F
    HALL, EJ
    OLIVER, R
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1959, 32 (378) : 421 - 422