Validated toxicological determination of 30 drugs of abuse as optimized derivatives in oral fluid by long column fast gas chromatography/electron impact mass spectrometry

被引:94
作者
Gunnar, T
Ariniemi, K
Lillsunde, P
机构
[1] Natl Publ Hlth Inst, Drug Res Unit, FIN-00300 Helsinki, Finland
[2] Aalto Univ, Inorgan & Analyt Chem Lab, Espoo 02015, Finland
来源
JOURNAL OF MASS SPECTROMETRY | 2005年 / 40卷 / 06期
关键词
oral fluid; drugs of abuse; fast gas chromatography/ mass spectrometry; quantitative determination; toxicological analysis;
D O I
10.1002/jms.846
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An analytical procedure was developed for the simultaneous sensitive identification, screening and quantitation of 30 drugs of abuse using 250 mu l of human oral fluid. The method employs sequential mixed-mode solid-phase extraction (SPE), optimized derivative formation and long-column fast gas chromatography/electron impact mass spectrometry (GC/EI-MS). After sequential SPE elution, the most sensitive and stable derivatives were formed by taking careful account of the characteristics of the active functional groups and possible steric hindrances affecting derivatization chemistry. Amphetamine-type stimulant drugs were acylated with heptafluorobutyric anhydride, benzodiazepines and Delta(9)-tetrahydrocannabinol were silylated with N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide and benzoylecgonine, codeine, ethylmorphine, 6-monoacetylmorphine, morphine, pholcodine, buprenorphine and norbuprenorphine with N-methyl-N-(trimethylsilyl)trifluoroacetamide. In addition, the following analytes were included: methadone, cocaine, alprazolam, midazolam, fentanyl and zolpidem. In GC separation, fast temperature ramping and high carrier gas flow-rate combined with long 30 m columns of i.d. 0.32 mm offered a reduction in analysis time and sharp peak shapes while still maintaining sufficient resolution and high sample capacity. Validated parameters including selectivity, linearity, accuracy, intra- and inter-day precision, extraction efficiency and limit of quantitation were all within required limits. In contrast to previously published methods, this single procedure is suitable for the simultaneous toxicological determination of the most common illicit drugs and benzodiazepines, and also zolpidem, in a small amount of oral fluid. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:739 / 753
页数:15
相关论文
共 42 条
[11]   SALIVARY EXCRETION OF DRUGS IN CHILDREN - THEORETICAL AND PRACTICAL ISSUES IN THERAPEUTIC DRUG-MONITORING [J].
GORODISCHER, R ;
KOREN, G .
DEVELOPMENTAL PHARMACOLOGY AND THERAPEUTICS, 1992, 19 (04) :161-177
[12]   Determination of 14 benzodiazepines and hydroxy metabolites, zaleplon and zolpidem as tert-butyldimethylsilyl derivatives compared with other common silylating reagents in whole blood by gas chromatography-mass spectrometry [J].
Gunnar, T ;
Ariniemi, K ;
Lillsunde, P .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 818 (02) :175-189
[13]   Validated semiquantitative/quantitative screening of 51 drugs in whole blood as silylated derivatives by gas chromatography-selected ion monitoring mass spectrometry and gas chromatography electron capture detection [J].
Gunnar, T ;
Mykkänen, S ;
Ariniemi, K ;
Lillsunde, P .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 806 (02) :205-219
[14]   FACTORS INFLUENCING THE SALIVA PLASMA RATIO OF DRUGS [J].
HAECKEL, R .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1993, 694 :128-142
[15]   Determination of cannabinoids in water and human saliva by solid-phase microextraction and quadrupole ion trap gas chromatography mass spectrometry [J].
Hall, BJ ;
Satterfield-Doerr, M ;
Parikh, AR ;
Brodbelt, JS .
ANALYTICAL CHEMISTRY, 1998, 70 (09) :1788-1796
[16]  
HOLD KM, 1996, INT J DRUG TESTING, V1, P1
[17]   The simultaneous determination of codeine, morphine, hydrocodone, hydromorphone, 6-acetylmorphine, and oxycodone in hair and oral fluid [J].
Jones, J ;
Tomlinson, K ;
Moore, C .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2002, 26 (03) :171-175
[18]   Single-step procedure for gas chromatography-mass spectrometry screening and quantitative determination of amphetamine-type stimulants and related drugs in blood, serum, oral fluid and urine samples [J].
Kankaanpää, A ;
Gunnar, T ;
Ariniemi, K ;
Lillsunde, P ;
Mykkänen, S ;
Seppälä, T .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 810 (01) :57-68
[19]   The diagnostic applications of saliva - A review [J].
Kaufman, E ;
Lamster, IB .
CRITICAL REVIEWS IN ORAL BIOLOGY & MEDICINE, 2002, 13 (02) :197-212
[20]  
Kaufman MS, 1996, J MASS SPECTROM, V31, P913