Baseline resolution of two peptides, RVMRGMR and RSHRGHR, of neutral monoisotopic mass, similar to 904 Da, has been achieved by microelectrospray ionization Fourier transform ion cyclotron resonance mass spectrometry at a mass resolving power of similar to 3300000. The elemental compositions of these molecules differ by N4O vs S2H8 (0.000 45 Da), which is less than one electron's mass (0.000 55 Da). This result establishes a new record for the smallest resolved mass difference between any two molecules. This achievement is made possible by a combination of high magnetic field (9.4 T), large-diameter (4-in.) Penning trap, and low ion density. The implications for proteomics based on accurate mass measurements are discussed briefly.
引用
收藏
页码:647 / 650
页数:4
相关论文
共 37 条
  • [1] The SWISS-PROT protein sequence database and its supplement TrEMBL in 2000
    Bairoch, A
    Apweiler, R
    [J]. NUCLEIC ACIDS RESEARCH, 2000, 28 (01) : 45 - 48
  • [2] FOURIER-TRANSFORM ELECTROSPRAY INSTRUMENTATION FOR TANDEM HIGH-RESOLUTION MASS-SPECTROMETRY OF LARGE MOLECULES
    BEU, SC
    SENKO, MW
    QUINN, JP
    WAMPLER, FM
    MCLAFFERTY, FW
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) : 557 - 565
  • [3] Beynon J., 1963, MASS ABUNDANCE TABLE
  • [4] TIME-BASE MODULATION FOR THE CORRECTION OF CYCLOTRON FREQUENCY-SHIFTS OBSERVED IN LONG-LIVED TRANSIENTS FROM FOURIER-TRANSFORM ION-CYCLOTRON-RESONANCE MASS-SPECTROMETRY OF ELECTROSPRAYED BIOPOLYMERS
    BRUCE, JE
    ANDERSON, GA
    HOFSTADLER, SA
    WINGER, BE
    SMITH, RD
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (08) : 700 - 703
  • [5] CHEN L, 1986, CHEMOMETRICS INTELLI, V1, P51
  • [6] ACCURATE ATOMIC MASS MEASUREMENTS FROM PENNING TRAP MASS COMPARISONS OF INDIVIDUAL IONS
    DIFILIPPO, F
    NATARAJAN, V
    BRADLEY, M
    PALMER, F
    PRITCHARD, DE
    [J]. PHYSICA SCRIPTA, 1995, T59 : 144 - 154
  • [7] Digital quadrature heterodyne detection for high-resolution Fourier transform ion cyclotron resonance mass spectrometry
    Drader, JJ
    Shi, SDH
    Blakney, GT
    Hendrickson, CL
    Laude, DA
    Marshall, AG
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (20) : 4758 - 4763
  • [8] DRADER JJ, 1999, 50 PITTSB C AN CHEM
  • [9] Application of micro-electrospray liquid chromatography techniques to FT-ICR MS to enable high-sensitivity biological analysis
    Emmett, MR
    White, FM
    Hendrickson, CL
    Shi, SDH
    Marshall, AG
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (04) : 333 - 340
  • [10] MICRO-ELECTROSPRAY MASS-SPECTROMETRY - ULTRA-HIGH-SENSITIVITY ANALYSIS OF PEPTIDES AND PROTEINS
    EMMETT, MR
    CAPRIOLI, RM
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (07) : 605 - 613