Application of micro-electrospray liquid chromatography techniques to FT-ICR MS to enable high-sensitivity biological analysis

被引:181
作者
Emmett, MR [1 ]
White, FM [1 ]
Hendrickson, CL [1 ]
Shi, SDH [1 ]
Marshall, AG [1 ]
机构
[1] Florida State Univ, Ctr Interdisciplinary Magnet Resonance, Natl High Magnet Field Lab, Tallahassee, FL 32310 USA
关键词
D O I
10.1016/S1044-0305(97)00287-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A microbore electrospray (ESI) injection system has been adapted to our 9.4-tesla ESI FT-ICR mass spectrometer, greatly enhancing the stability and sensitivity of the system. Spray was generated from micro-ESI needles made from sharply tapered, polished fused silica capillaries of 25 to 50 mu m inner diameter. Micro-ESI permits low-level sample analysis by constant infusion at sub-mu L/min flow rate over a wide range of solvent conditions in both positive-and negative-ion mode. The system is flexible and allows rapid conversion to allow routine LC/MS analysis on low-level mixtures presented in biological media. LC/MS analyses were accomplished by replacing micro-ESI needles with capillaries packed with reverse phase retention media to permit analyte concentration and purification prior to analysis (micro-ESI/LC). A unique nano-flow LC pumping system was developed, capable of producing a true unsplit solvent gradient at flow rates below 1 mu L/min. The micro-ESI/LC FT-ICR system produces mass spectra from a mixture of three neuroactive peptides at a concentration of 500 amol/mu L (5 fmol each total loaded) in biological salts with baseline separation, signal-to-noise ratio of >10:1 and mass resolving power >5000. These results represent a reduction in detection limit by a factor of similar to 2 x 10(6) over the best previously published LC/FT-ICR MS data. (C) 1998 American Society for Mass Spectrometry.
引用
收藏
页码:333 / 340
页数:8
相关论文
共 32 条
[1]   MICRO-ELECTROSPRAY - ZEPTOMOLE-ATTOMOLE PER MICROLITER SENSITIVITY FOR PEPTIDES [J].
ANDREN, PE ;
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (09) :867-869
[2]  
Bateman KP, 1997, RAPID COMMUN MASS SP, V11, P307
[3]   OPEN TRAPPED ION CELL GEOMETRIES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 112 (2-3) :215-230
[4]   AN ELECTROSPRAY-IONIZATION MASS-SPECTROMETER WITH NEW FEATURES [J].
CHOWDHURY, SK ;
KATTA, V ;
CHAIT, BT .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (03) :81-87
[5]   Specific molecular mass detection of endogenously released neuropeptides using in vivo microdialysis mass spectrometry [J].
Emmett, MR ;
Andren, PE ;
Caprioli, RM .
JOURNAL OF NEUROSCIENCE METHODS, 1995, 62 (1-2) :141-147
[6]   MICRO-ELECTROSPRAY MASS-SPECTROMETRY - ULTRA-HIGH-SENSITIVITY ANALYSIS OF PEPTIDES AND PROTEINS [J].
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (07) :605-613
[7]   ELECTROSPRAY IONIZATION-PRINCIPLES AND PRACTICE [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
MASS SPECTROMETRY REVIEWS, 1990, 9 (01) :37-70
[8]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[9]   Stored waveform inverse Fourier transform (SWIFT) ion excitation in trapped-ion mass spectometry: Theory and applications [J].
Guan, SH ;
Marshall, AG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1996, 157 :5-37
[10]   FOURIER-TRANSFORM MASS-SPECTROMETRY OF LARGE MOLECULES BY ELECTROSPRAY IONIZATION [J].
HENRY, KD ;
WILLIAMS, ER ;
WANG, BH ;
MCLAFFERTY, FW ;
SHABANOWITZ, J ;
HUNT, DF .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1989, 86 (23) :9075-9078