Extended coverage first-pass perfusion imaging using slice-interleaved TSENSE

被引:56
作者
Kellman, P [1 ]
Derbyshire, JA [1 ]
Agyeman, KO [1 ]
McVeigh, ER [1 ]
Arai, AE [1 ]
机构
[1] NHLBI, Cardiac Energet Lab, DHHS, NIH, Bethesda, MD 20892 USA
关键词
MRI; heart; perfusion; contrast agent; SENSE; TSENSE;
D O I
10.1002/mrm.10663
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Parallel imaging applied to first-pass, contrast-enhanced cardiac MR can yield greater spatial coverage for a fixed temporal resolution. The method combines rate R = 2 acceleration using TSENSE with shot-to-shot interleaving of two slices. The rootR SNR loss is largely compensated for by a longer effective repetition time (TR) and increased flip angle associated with slice interleaving. In this manner, increased spatial coverage is achieved while comparable or better image quality is maintained. Single-heartbeat temporal resolution was accomplished with spatial coverage of eight slices at heart rates up to 71 bpm, six slices up to 95 bpm, and four slices up to 143 bpm. Experiments in normal subjects (N = 6) were performed to assess signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) values. Published 2003 Wiley-Liss, Inc.(dagger).
引用
收藏
页码:200 / 204
页数:5
相关论文
共 14 条
  • [1] Magnetic resonance myocardial first-pass perfusion imaging: Parameter optimization for signal response and cardiac coverage
    Bertschinger, KM
    Nanz, D
    Buechi, M
    Luescher, TF
    Marincek, B
    von Schulthess, GK
    Schwitter, J
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (05) : 556 - 562
  • [2] Comparison of temporal filtering methods for dynamic contrast MRI myocardial perfusion studies
    Di Bella, EVR
    Wu, YJ
    Alexander, AL
    Parker, DL
    Green, D
    McGann, CJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (05) : 895 - 902
  • [3] Improved coverage in dynamic contrast-enhanced cardiac MRI using interleaved gradient-echo EPI
    Ding, SJ
    Wolff, SD
    Epstein, FH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) : 514 - 519
  • [4] Epstein FH, 2000, RADIOLOGY, V217, P291
  • [5] HERZKA DA, 2000, P 8 ANN M ISMRM DENV, P1529
  • [6] Kellman P, 2000, MAGNET RESON MED, V44, P933, DOI 10.1002/1522-2594(200012)44:6<933::AID-MRM15>3.0.CO
  • [7] 2-I
  • [8] Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)
    Kellman, P
    Epstein, FH
    McVeigh, ER
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) : 846 - 852
  • [9] Madore B, 1999, MAGNET RESON MED, V42, P813, DOI 10.1002/(SICI)1522-2594(199911)42:5<813::AID-MRM1>3.0.CO
  • [10] 2-S