Radiation dose of non-enhanced chest CT can be reduced 40% by using iterative reconstruction in image space

被引:147
作者
Hu, X. H. [1 ]
Ding, X. F. [1 ]
Wu, R. Z. [2 ]
Zhang, M. M. [1 ]
机构
[1] Zhejiang Univ, Coll Med, Affiliated Hosp 2, Hangzhou 310009, Zhejiang, Peoples R China
[2] Siemens Healthcare, Beijing, Peoples R China
关键词
AUTOMATIC EXPOSURE CONTROL; LOW-TUBE-VOLTAGE; ABDOMINAL CT; CORONARY-ANGIOGRAPHY; TOMOGRAPHY; QUALITY; OPTIMIZATION; FEASIBILITY; STRATEGIES; EXPERIENCE;
D O I
10.1016/j.crad.2011.04.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
AIM: To evaluate the image quality and dose reduction capability of non-enhanced chest computed tomography (CT) examinations using iterative reconstruction in image space (IRIS). MATERIALS AND METHODS: A CT water phantom was scanned at 120 kV/150 mAs and 100 kV/270 mAs as the reference, and the tube current was decreased in 10% intervals down to 40% of the reference value. Image noise was evaluated and compared between filtered back-projection (FBP) and IRIS reconstructed data. In the patient study, 90 patients underwent non-enhanced chest CT examinations; the patients were randomly assigned into three groups: group A (n = 30) standard dose protocol, 120 kV/110 mAs; group B (n = 30) low dose, 100 kV/110 mAs; group C (n = 30) low dose, 120 kV/67 mAs. All images were reconstructed by FBP and IRIS algorithm using matched kernels of B30 and 130. The objective image noise (01N), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of the aorta and latissimus dorsi were measured. The subjective image quality and noise were scored using a three-point scale by two experienced radiologists. The results of the subjective and objective image assessment were compared between groups B and C (low dose) IRIS and group A (standard dose) FBP. RESULTS: The phantom study showed comparable image noise between the scans using 60% dose with IRIS and 100% dose with FBP for both 120 and 100 kV. In the patient study, groups A. B, and C had effective dose of 3.81 +/- 0.43, 2.40 +/- 0.19, and 2.41 +/- 0.15 mSv. IRIS significantly improved the OIN, SNR, and CNR compared with FBP for the same patient. The OIN, SNR, and CNR using IRIS in group B and C were improved or comparable to those in group A using FBR No significant difference was found in subjective image quality and noise between groups B and C using IRIS and group A using FBP. CONCLUSION: Compared with FBP, IRIS can maintain or improve image quality on unenhanced chest CT image reconstruction while saving 40% radiation dose. (C) 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1023 / 1029
页数:7
相关论文
共 32 条
[1]
[Anonymous], 16262 EUR
[2]
Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer [J].
Brenner, DJ .
RADIOLOGY, 2004, 231 (02) :440-445
[3]
Feasibility of MDCT colonography in ultra-low-dose technique in the detection of colorectal lesions: Comparison with high-resolution video colonoscopy [J].
Cohnen, M ;
Vogt, C ;
Beck, A ;
Andersen, K ;
Heinen, W ;
vom Dahl, S ;
Aurich, V ;
Haeussinger, D ;
Moedder, U .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (05) :1355-1359
[4]
Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography [J].
Einstein, Andrew J. ;
Henzlova, Milena J. ;
Rajagopalan, Sanjay .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03) :317-323
[5]
European Commission, 2000, EUR16262EN EUR COMM
[6]
Prospective ECG triggering versus low-dose retrospective ECG-gated 128-channel CT coronary angiography: comparison of image quality and radiation dose [J].
Feng, Q. ;
Yin, Y. ;
Hua, X. ;
Zhu, R. ;
Hua, J. ;
Xu, J. .
CLINICAL RADIOLOGY, 2010, 65 (10) :809-814
[7]
Helical CT in children: Technical considerations and body applications [J].
Frush, DP ;
Donnelly, LF .
RADIOLOGY, 1998, 209 (01) :37-48
[8]
Principles of CT and CT Technology [J].
Goldman, Lee W. .
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2007, 35 (03) :115-128
[9]
Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study [J].
Hara, Amy K. ;
Paden, Robert G. ;
Silva, Alvin C. ;
Kujak, Jennifer L. ;
Lawder, Holly J. ;
Pavlicek, William .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) :764-771
[10]
Image quality and radiation exposure at pulmonary CT angiography with 100-or 120-kVp protocol: prospective randomized study [J].
Heyer, Christoph M. ;
Mohr, Patrick S. ;
Lemburg, Stefan P. ;
Peters, Soeren A. ;
Nicolas, Volkmar .
RADIOLOGY, 2007, 245 (02) :577-583