High-accuracy detector calibration at the PTB four-crystal monochromator beamline

被引:201
作者
Krumrey, M [1 ]
Ulm, G [1 ]
机构
[1] Phys Tech Bundesanstalt, Xray Radiometry Lab, D-10587 Berlin, Germany
关键词
X-ray detector calibration; four-crystal monochromator; semiconductor photodiodes;
D O I
10.1016/S0168-9002(01)00598-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A four-crystal monochromator beamline has been installed by the Physikalisch-Technische Bundesanstalt at a bending magnet of the electron storage ring BESSY II. The monochromatic radiation with very high spectral purity and high spectral resolution in the photon energy range from 1.75 to 10keV is used to calibrate detectors by comparison to a cryogenic electrical substitution radiometer as primary detector standard with relative uncertainties well below 1%, This is one order of magnitude better than all calibrations of non-energy-dispersive detectors in this spectral range previously performed. The beamline is also used for the characterization of optical components. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1175 / 1178
页数:4
相关论文
共 9 条
[1]   X-ray detector calibration in the PTB radiometry laboratory at the electron storage ring BESSY II [J].
Beckhoff, B ;
Klein, R ;
Krumrey, M ;
Scholze, F ;
Thornagel, R ;
Ulm, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2) :480-483
[2]   Micro-channel plate based X-ray optics [J].
Beijersbergen, M ;
Bavdaz, M ;
Peacock, A ;
Tomaselli, E ;
Fraser, G ;
Brunton, A ;
Flyckt, E ;
Krumrey, M ;
Souvorov, A .
EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 :452-458
[3]   An X-ray photon-counting imaging spectrometer based on a Ta absorber with four superconducting tunnel junctions [J].
den Hartog, R ;
Verhoeve, P ;
Martin, D ;
Rando, N ;
Peacock, A ;
Krumrey, M ;
Goldie, DJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2) :278-282
[4]   AN X-RAY MONOCHROMATOR CRYSTAL WHICH DETECTS THE BRAGG CONDITION [J].
JACH, T ;
NOVOTNY, D ;
CARVER, G ;
GEIST, J ;
SPAL, RD .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 263 (2-3) :522-524
[5]   Components for the X-ray radiometry beamline at BESSY II [J].
Krumrey, M ;
Herrmann, C ;
Muller, P ;
Ulm, G .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :788-790
[6]   Synchrotron-radiation-based cryogenic radiometry in the X-ray range [J].
Krumrey, M ;
Herrmann, C ;
Müller, P ;
Ulm, G .
METROLOGIA, 2000, 37 (05) :361-364
[7]   Design of a four-crystal monochromator beamline for radiometry at BESSY II [J].
Krumrey, M .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :6-9
[8]   Synchrotron-radiation-operated cryogenic electrical-substitution radiometer as the high-accuracy primary detector standard in the ultraviolet, vacuum-ultraviolet, and soft-x-ray spectral ranges [J].
Rabus, H ;
Persch, V ;
Ulm, G .
APPLIED OPTICS, 1997, 36 (22) :5421-5440
[9]   Mean energy required to produce an electron-hole pair in silicon for photons of energies between 50 and 1500 eV [J].
Scholze, F ;
Rabus, H ;
Ulm, G .
JOURNAL OF APPLIED PHYSICS, 1998, 84 (05) :2926-2939