Synchrotron-radiation-based cryogenic radiometry in the X-ray range

被引:9
作者
Krumrey, M [1 ]
Herrmann, C [1 ]
Müller, P [1 ]
Ulm, G [1 ]
机构
[1] PTB, D-10587 Berlin, Germany
关键词
D O I
10.1088/0026-1394/37/5/3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Physikalisch-Technische Bundesanstalt (PTB) has installed an X-ray radiometry beamline at the new electron storage ring BESSY II. The synchrotron radiation is monochromatized by a four-crystal monochromator in the photon-energy range from 1.75 keV to 10 keV. The known radiant power, determined with a cryogenic electrical-substitution radiometer (ESR) as primary detector standard, is used for the calibration of detectors such as semiconductor photodiodes. Relative uncertainties of spectral responsivity well below 1% have been achieved.
引用
收藏
页码:361 / 364
页数:4
相关论文
共 13 条
[1]   X-ray detector calibration at CEA/Bruyeres-le-Chatel [J].
Beck, L ;
Stemmler, P ;
Ban, G ;
Villette, B ;
Frotte, V ;
Bizeuil, C ;
Boutin, JY ;
Nazet, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 369 (2-3) :401-406
[2]   PHOTOELECTRIC QUANTUM EFFICIENCIES AND FILTER WINDOW ABSORPTION-COEFFICIENTS FROM 20-EV TO 10-KEV [J].
DAY, RH ;
LEE, P ;
SALOMAN, EB ;
NAGEL, DJ .
JOURNAL OF APPLIED PHYSICS, 1981, 52 (11) :6965-6973
[3]   MEASUREMENTS OF THE ABSOLUTE SPECTRAL SENSITIVITY OF X-RAY SEMICONDUCTOR-DETECTORS IN THE PHOTON ENERGY-RANGE OF 1.5-15 KEV USING WHITE SR BEAM OF THE VEPP-3 STORAGE-RING [J].
DOLBNYA, IP ;
MAKAROV, OA ;
MEZENTSEV, NA ;
PINDYURIN, VF ;
SUBBOTIN, AN .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 359 (1-2) :427-431
[4]   Quantum efficiencies of gold and copper photocathodes in the VUV and X-ray range [J].
Henneken, H ;
Scholze, F ;
Krumrey, M ;
Ulm, G .
METROLOGIA, 2000, 37 (05) :485-488
[5]   High accuracy calibration of the HXDS HPGe detector at the PTB radiometry laboratory at BESSY [J].
Kraft, S ;
Scholze, F ;
Thornagel, R ;
Ulm, G .
EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 :101-112
[6]   Components for the X-ray radiometry beamline at BESSY II [J].
Krumrey, M ;
Herrmann, C ;
Muller, P ;
Ulm, G .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :788-790
[7]   Design of a four-crystal monochromator beamline for radiometry at BESSY II [J].
Krumrey, M .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :6-9
[8]   Characterization of photodiodes as transfer detector standards in the 120 nm to 600 nm spectral range [J].
Kuschnerus, P ;
Rabus, H ;
Richter, M ;
Scholze, F ;
Werner, L ;
Ulm, G .
METROLOGIA, 1998, 35 (04) :355-362
[9]   Synchrotron-radiation-operated cryogenic electrical-substitution radiometer as the high-accuracy primary detector standard in the ultraviolet, vacuum-ultraviolet, and soft-x-ray spectral ranges [J].
Rabus, H ;
Persch, V ;
Ulm, G .
APPLIED OPTICS, 1997, 36 (22) :5421-5440
[10]   Mean energy required to produce an electron-hole pair in silicon for photons of energies between 50 and 1500 eV [J].
Scholze, F ;
Rabus, H ;
Ulm, G .
JOURNAL OF APPLIED PHYSICS, 1998, 84 (05) :2926-2939