X-ray detector calibration at CEA/Bruyeres-le-Chatel

被引:11
作者
Beck, L
Stemmler, P
Ban, G
Villette, B
Frotte, V
Bizeuil, C
Boutin, JY
Nazet, C
机构
[1] Commsrt. à l'Energie Atomique, Service CEM/MR, 91680 Bruyeres-le-Chatel
关键词
D O I
10.1016/S0168-9002(96)80018-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
At CEA/Bruyeres-le-Chatel (Service GEM), then are facilities to calibrate X-ray detectors from 200 eV to 100 keV, with an accuracy of 4% at high energies (E > 3 keV). The source is the direct radiation from the X-ray tubes [C-K alpha (277 eV) to Ti-K alpha K beta (4.51/4.93 keV)] or fluorescence emission from secondary targets [ME(K alpha) (1.25 keV) to U-K alpha (98 keV)]. In addition, calibrations are carried out with the synchrotron radiation of the Super-AGO storage ring (LURE-Orsay), by selecting the monoenergetic beams with a double crystal monochromator which is tunable between 0.8 and 8 keV. The resolution is better than 1 eV. This last tool is very useful in the study of the absorption edges of the detector compounds (for example, Si K-edge and Ar K-edge). Some examples are presented of results obtained between 1 and 50 keV, with special reference to high flux detectors such as gold photocathodes and silicon avalanche photodiodes. Thick silicon photodiodes (for the high energy range) were also calibrated.
引用
收藏
页码:401 / 406
页数:6
相关论文
共 24 条
[1]  
BAN G, UNPUB NUCL INSTR MET
[2]   X-UV MULTILAYER REFLECTIVITY TESTS USING WINDOWLESS SOFT X-RAYS TUBE AND SYNCHROTRON SOURCE [J].
BARCHEWITZ, R ;
MARMORET, R .
REVUE DE PHYSIQUE APPLIQUEE, 1988, 23 (10) :1661-1674
[3]   TIME-RESOLVED DETECTION OF X-RAYS USING LARGE-AREA AVALANCHE PHOTODIODES [J].
BARON, AQR ;
RUBY, SL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 343 (2-3) :517-526
[4]   MEASUREMENT OF THE X-RAY SPECTROMETRIC PROPERTIES OF CESIUM HYDROPHTHALATE (CSAP) CRYSTAL WITH THE SYNCHROTRON-RADIATION [J].
BECK, L ;
STEMMLER, P ;
LEGRAND, F .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1601-1603
[5]   ABSOLUTE CALIBRATION OF A PHOTODIODE-ARRAY WITH THE USE OF THE SYNCHROTRON-RADIATION IN THE RANGE OF 1-10 KEV [J].
BECK, L ;
BIZEUIL, C ;
SOULLIE, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :2339-2341
[6]   STABILITY AND QUANTUM EFFICIENCY PERFORMANCE OF SILICON PHOTODIODE DETECTORS IN THE FAR ULTRAVIOLET [J].
CANFIELD, LR ;
KERNER, J ;
KORDE, R .
APPLIED OPTICS, 1989, 28 (18) :3940-3943
[7]  
FERRER JL, 1994, ESRF US M
[8]   THE CHARACTERIZATION OF X-RAY PHOTO-CATHODES IN THE 0.1-10-KEV PHOTON ENERGY REGION [J].
HENKE, BL ;
KNAUER, JP ;
PREMARATNE, K .
JOURNAL OF APPLIED PHYSICS, 1981, 52 (03) :1509-1520
[9]  
HENKE BL, 1982, ATOM DATA NUCL DATA, V27, P100
[10]  
IDIR M, 1993, IN PRESS P XRAY MICR, V4