Dose quantities for characterization of patients' exposure to radiation in computed tomography and their significance for risk estimation

被引:4
作者
Hidajat, N
Schroder, RJ
Wolf, M
Vogl, T
Felix, R
机构
[1] Strahlenklinik und Poliklinik, Virchow-Klin. der Med. Fakultät, Humboldt-Universität zu Berlin
[2] Strahlenklinik und Poliklinik, Virchow-Klin. der Med. Fakultät, Humboldt-Universität zu Berlin, D-13353 Berlin
来源
RADIOLOGE | 1997年 / 37卷 / 06期
关键词
computed tomography dose index (CTDI); multiple scan average dose (MSAD); dose on axis of rotation;
D O I
10.1007/s001170050240
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In order to evaluate patients' exposure to radiation in computed tomography, dose quantities such as the computed tomography dose index (CTDI), multiple scan average dose (MSAD) and dose free in air on the axis of rotation are used. The CTDI and the MSAD, derivable from the CTDI, are a good measure for the absorbed doses in the examined volume, but they do not take the biological sensitivity of the organs into account and do not describe the radiogenic risk that is actually relevant for patients and doctors. The dose on the axis of rotation is not an accurate measure of the effective dose and the radiogenic risk. The declaration of a limit for the dose on the axis of rotation should take the different regions into account, in order to guarantee acceptable image quality on one hand and to avoid an unnecessarily high risk on the other side. As physical dose quantities, the CTDI, MSAD and dose on the axis of rotation are useful to characterize and differentiate between programs and systems concerning radiation exposure.
引用
收藏
页码:464 / 469
页数:6
相关论文
共 30 条
[11]   Calculated organ doses and effective dosage for CT examination of the thorax and abdomen: Are these doses realistic? [J].
Hidajat, N ;
Vogl, T ;
Schroder, RJ ;
Felix, R .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1996, 164 (05) :382-387
[12]  
HIDAJAT N, 1995, RADIOLOGE, V35, pS164
[13]   RADIATION EXPOSURE FROM EMI SCANNER MULTIPLE SCANS [J].
HORSLEY, RJ ;
PETERS, VG .
BRITISH JOURNAL OF RADIOLOGY, 1976, 49 (585) :810-811
[15]   Calculation of computed tomography dose index to effective dose conversion factors based on measurement of the dose profile along the fan shaped beam [J].
Jansen, JTM ;
Geleijns, J ;
Zweers, D ;
Schultz, FW ;
Zoetelief, J .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (817) :33-41
[16]  
Jucius R A, 1977, P SOC PHOTO-OPT INS, V127, P286
[17]   RADIATION-DOSIMETRY FOR ELECTRON-BEAM CT [J].
MCCOLLOUGH, CH ;
ZINK, FE ;
MORIN, RL .
RADIOLOGY, 1994, 192 (03) :637-643
[18]   PATIENT DOSAGE IN COMPUTED TOMOGRAPHY [J].
MCCULLOUGH, EC ;
PAYNE, JT .
RADIOLOGY, 1978, 129 (02) :457-463
[19]   PERFORMANCE EVALUATION AND QUALITY ASSURANCE OF COMPUTED TOMOGRAPHY SCANNERS, WITH ILLUSTRATIONS FROM EMI, ACTA, AND DELTA SCANNERS [J].
MCCULLOUGH, EC ;
PAYNE, JT ;
BAKER, HL ;
HATTERY, RR ;
SHEEDY, PF ;
STEPHENS, DH ;
GEDGAUDUS, E .
RADIOLOGY, 1976, 120 (01) :173-188
[20]  
MCGHEE PL, 1994, CAN ASSOC RADIOL J, V45, P124