0804 ; 080401 ; 081102 ;
摘要
We report a measurement of the quantum efficiency of a charge coupled device (CCD) with a simple method and report a resultant quantum efficiency in the energy range from 0.47 to 9 keV. The CCD is a front side illuminated device and is fabricated by Hamamatsu Photonics K.K. The quantum efficiency for 4.5 keV x rays is 11% for the single pixel events, 33% for the spectroscopic events, and 60% for flux mode operation. We present the quantum efficiency as a function of the energy. (C) 1998 American Institute of Physics. [S0034-6748(98)02911-6].
引用
收藏
页码:3746 / 3750
页数:5
相关论文
共 18 条
  • [1] X-ray CCD calibration for the AXAF CCD imaging spectrometer
    Bautz, M
    Kissel, S
    Prigozhin, G
    Jones, S
    Isobe, T
    Manning, H
    Pivovaroff, M
    Ricker, G
    Woo, J
    [J]. EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VII, 1996, 2808 : 170 - 181
  • [2] CCD SOFT-X-RAY IMAGING SPECTROMETER FOR THE ASCA SATELLITE
    BURKE, BE
    MOUNTAIN, RW
    DANIELS, PJ
    COOPER, MJ
    DOLAT, VS
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (01) : 375 - 385
  • [3] Gendreau K.C., 1995, THESIS MIT
  • [4] Low energy response of silicon pn-junction detector
    Hartmann, R
    Hauff, D
    Lechner, P
    Richter, R
    Struder, L
    Kemmer, J
    Krisch, S
    Scholze, F
    Ulm, G
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3) : 191 - 196
  • [5] Continuum x-ray source as a calibration system for charge coupled devices
    Hashimotodani, K
    Toneri, T
    Kitamoto, S
    Tsunemi, H
    Hayashida, K
    Miyata, E
    Katayama, K
    Kohomura, T
    Asakura, R
    Koyama, K
    Yamamoto, K
    Miyaguchi, K
    Suzuki, H
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02) : 392 - 395
  • [6] VARIABLE LINE-SPACE GRATINGS - NEW DESIGNS FOR USE IN GRAZING-INCIDENCE SPECTROMETERS
    HETTRICK, MC
    BOWYER, S
    [J]. APPLIED OPTICS, 1983, 22 (24): : 3921 - 3924
  • [7] ABERRATIONS OF VARIED LINE-SPACE GRAZING-INCIDENCE GRATINGS IN CONVERGING LIGHT-BEAMS
    HETTRICK, MC
    [J]. APPLIED OPTICS, 1984, 23 (18): : 3221 - 3235
  • [8] Thin-gate front side-illuminated versus back side-illuminated charge-coupled devices for X-ray astronomy
    Kraft, RP
    Burrows, DN
    Garmire, GP
    Nousek, JA
    [J]. ASTROPHYSICAL JOURNAL, 1996, 466 (01) : L51 - L54
  • [9] Quantum efficiency calibration of AXAF CCDs from 2-10 keV
    Manning, HL
    Jones, SE
    Kissel, SE
    Bautz, MW
    Ricker, GR
    [J]. EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VII, 1996, 2808 : 23 - 33
  • [10] Owens A, 1996, X-RAY SPECTROM, V25, P33, DOI 10.1002/(SICI)1097-4539(199601)25:1<33::AID-XRS135>3.3.CO