Direct electrocatalytic reduction of hydrogen peroxide based on Nafion and copper oxide nanoparticles modified Pt electrode

被引:183
作者
Miao, Xiang-Min [1 ]
Yuan, Ruo [1 ]
Chai, Ya-Qin [1 ]
Shi, Yin-Tao [1 ]
Yuan, Yan-Yu [1 ]
机构
[1] SW Univ, Chongqing Key Lab Analyt Chem, Chongqing 400715, Peoples R China
基金
中国国家自然科学基金;
关键词
copper oxide nanoparticles; Nafion; hydrogen peroxide; platinum electrode;
D O I
10.1016/j.jelechem.2007.09.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel electrochemical sensor for the detection of hydrogen peroxide (H2O2) was proposed based on immobilizing Copper oxide nanoparticles (nano-CuO) on Nafion (Nf) membrane coated Pt electrode. Scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used to confirm the successful stepwise assembly procedure of the sensor. The electrocatalytical behaviors of the sensor were also investigated by CV and Chronoamperometry. Tests showed that nano-CuO exhibited a remarkable electrocatalytic activity for the reduction of H2O2. Under optimal conditions, the electrocatalytic response of the sensor was proportional to the H2O2 concentration in the range of 0.15 mu M-9.00 mM with a detection limit down to 0.06 mu M at 3 sigma, and achieved 95% of the steady-state current in 5 s. The low detection limit, wide linear range and high sensitivity of the sensor make it valuable for further application. (c) 2007 Published by Elsevier B.V.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 47 条
[11]   Performance of catalysts CuO-ZnO-Al2O3, CuO-ZnO-Al2O3-Pt-Rh, and Pt-Rh in a small reformer for hydrogen generation [J].
Huang, Chih-Yung ;
Sun, Yu-Ming ;
Chou, Chung-Yang ;
Su, Chin-Chia .
JOURNAL OF POWER SOURCES, 2007, 166 (02) :450-457
[12]   ACCURACY OF DETERMINATION OF HYDROGEN PEROXIDE BY CERATE OXIDIMETRY [J].
HURDIS, EC ;
ROMEYN, H .
ANALYTICAL CHEMISTRY, 1954, 26 (02) :320-325
[13]   CuO-doped BSST thick film resistors for ppb level H2S gas sensing at room temperature [J].
Jain, G. H. ;
Patil, L. A. .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (01) :246-253
[14]  
JULIAN M, 2004, ELECTROCHIM ACTA, V494, P589
[15]   Controlled synthesis of multi-armed CdS nanorod architectures using monosurfactant system [J].
Jun, YW ;
Lee, SM ;
Kang, NJ ;
Cheon, J .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (21) :5150-5151
[16]   Flow-through micro sensor using immobilized peroxidase with chemiluminometric FIA system for determining hydrogen peroxide [J].
Kiba, N ;
Tokizawa, T ;
Kato, S ;
Tachibana, M ;
Tani, K ;
Koizumi, H ;
Edo, M ;
Yonezawa, E .
ANALYTICAL SCIENCES, 2003, 19 (06) :823-827
[17]  
Knorre H., 1975, GALVANOTECHNIK, V66, P374
[18]   Synthesis of size-monodisperse CdS nanocrystals using phosphatidylcholine vesicles as true reaction compartments [J].
Korgel, BA ;
Monbouquette, HG .
JOURNAL OF PHYSICAL CHEMISTRY, 1996, 100 (01) :346-351
[19]   Improved electrochemical properties of prussian blue by multi-walled carbon nanotubes [J].
Li, Zhenfeng ;
Chen, Jinhua ;
Li, Wang ;
Chen, Kun ;
Nie, Lihua ;
Yao, Shouzhuo .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 603 (01) :59-66
[20]   Low-potential amperometric determination of hydrogen peroxide with a carbon paste electrode modified with nanostructured cryptomelane-type manganese oxides [J].
Lin, YH ;
Cui, XL ;
Li, LY .
ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (02) :166-172