Simultaneous Detection of Six Diarrhea-Causing Bacterial Pathogens with an In-House PCR-Luminex Assay

被引:61
作者
Liu, Jie [1 ]
Gratz, Jean [1 ,3 ]
Maro, Athanasia [3 ]
Kumburu, Happy [3 ]
Kibiki, Gibson [3 ]
Taniuchi, Mami [1 ]
Howlader, Arif Mahmud [4 ]
Sobuz, Shihab U. [4 ]
Haque, Rashidul [4 ]
Talukder, Kaisar A. [4 ]
Qureshi, Shahida [5 ]
Zaidi, Anita [5 ]
Haverstick, Doris M. [2 ]
Houpta, Eric R. [1 ]
机构
[1] Univ Virginia, Dept Med, Div Infect Dis & Int Hlth, Charlottesville, VA 22903 USA
[2] Univ Virginia, Dept Pathol, Charlottesville, VA 22903 USA
[3] Kilimanjaro Christian Med Ctr, Moshi, Tanzania
[4] Int Ctr Diarrhoeal Dis Res, Dhaka 1000, Bangladesh
[5] Aga Khan Univ, Karachi, Pakistan
关键词
REAL-TIME PCR; ESCHERICHIA-COLI; MULTIPLEX PCR; CAMPYLOBACTER-JEJUNI; GASTROINTESTINAL PATHOGENS; ENTERIC PATHOGENS; VIBRIO-CHOLERAE; STOOL CULTURES; AEROLYSIN GENE; FECAL SAMPLES;
D O I
10.1128/JCM.05416-11
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Diarrhea can be caused by a range of pathogens, including several bacteria. Conventional diagnostic methods, such as culture, biochemical tests, and enzyme-linked immunosorbent assay (ELISA), are laborious. We developed a 7-plex PCR-Luminex assay to simultaneously screen for several of the major diarrhea-causing bacteria directly in fecal specimens, including pathogenic Aeromonas, Campylobacter jejuni, Campylobacter coli, Salmonella, Shigella, enteroinvasive Escherichia coli (EIEC), Vibrio, and Yersinia. We included an extrinsic control to verify extraction and amplification. The assay was first validated with reference strains or isolates and exhibited a limit of detection of 10(3) to 10(5) CFU/g of stool for each pathogen as well as quantitative detection up to 10(9) CFU/g. A total of 205 clinical fecal specimens from individuals with diarrhea, previously cultured for enteric pathogens and tested for Campylobacter by ELISA, were evaluated. Using these predicate methods as standards, sensitivities and specificities of the PCR-Luminex assay were 89% and 94% for Aeromonas, 89% and 93% for Campylobacter, 96% and 95% for Salmonella, 94% and 94% for Shigella, 92% and 97% for Vibrio, and 100% and 100% for Yersinia, respectively. All discrepant results were further examined by singleplex real-time PCR assays targeting different gene regions, which revealed 89% (55/62 results) concordance with the PCR-Luminex assay. The fluorescent signals obtained with this approach exhibited a statistically significant correlation with the cycle threshold (C-T) values from the cognate real-time PCR assays (P < 0.05). This multiplex PCR-Luminex assay enables sensitive, specific, and quantitative detection of the major bacterial causes of gastroenteritis.
引用
收藏
页码:98 / 103
页数:6
相关论文
共 50 条
  • [11] Three-Hour Molecular Detection of Campylobacter, Salmonella, Yersinia, and Shigella Species in Feces with Accuracy as High as That of Culture
    Cunningham, Scott A.
    Sloan, Lynne M.
    Nyre, Lisa M.
    Vetter, Emily A.
    Mandrekar, Jayawant
    Patel, Robin
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (08) : 2929 - 2933
  • [12] Improved Detection of Five Major Gastrointestinal Pathogens by Use of a Molecular Screening Approach
    de Boer, Richard F.
    Ott, Alewijn
    Kesztyus, Barbara
    Kooistra-Smid, Anna M. D.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (11) : 4140 - 4146
  • [13] Establishment of a real-time PCR-based approach for accurate quantification of bacterial RNA targets in water, using Salmonella as a model organism
    Fey, A
    Eichler, S
    Flavier, S
    Christen, R
    Höfle, MG
    Guzmán, CA
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2004, 70 (06) : 3618 - 3623
  • [14] Fujioka M, 2009, JPN J INFECT DIS, V62, P476
  • [15] Comparison of Premier CAMPY Enzyme Immunoassay (EIA), ProSpecT Campylobacter EIA, and ImmunoCard STAT! CAMPY Tests with Culture for Laboratory Diagnosis of Campylobacter Enteric Infections
    Granato, Paul A.
    Chen, Li
    Holiday, Iris
    Rawling, Russell A.
    Novak-Weekley, Susan M.
    Quinlan, Tammy
    Musser, Kimberlee A.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (11) : 4022 - 4027
  • [16] Practice guidelines for the management of infectious diarrhea
    Guerrant, RL
    Van Gilder, T
    Steiner, TS
    Thielman, NM
    Slutsker, L
    Tauxe, RV
    Hennessy, T
    Griffin, PM
    DuPont, H
    Sack, RB
    Tarr, P
    Neill, M
    Nachamkin, I
    Reller, LB
    Osterholm, MT
    Bennish, ML
    Pickering, LK
    [J]. CLINICAL INFECTIOUS DISEASES, 2001, 32 (03) : 331 - 351
  • [17] Detection of diarrheagenic Escherichia coli by use of melting-curve analysis and real-time multiplex PCR
    Guion, Chase E.
    Ochoa, Theresa J.
    Walker, Christopher M.
    Barletta, Francesca
    Cleary, Thomas G.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (05) : 1752 - 1757
  • [18] Optimisation of PCR reactions using primer chessboarding
    Gunson, R
    Gillespie, G
    Carman, WF
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2003, 26 (03) : 369 - 373
  • [19] Real-time PCR for the detection of Salmonella spp. in food:: An alternative approach to a conventional PCR system suggested by the FOOD-PCR project
    Hein, Ingeborg
    Flekna, Gabriele
    Krassnig, Martina
    Wagner, Martin
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2006, 66 (03) : 538 - 547
  • [20] NUCLEOTIDE-SEQUENCE AND TRANSCRIPTIONAL ANALYSIS OF THE AERCAERA REGION OF AEROMONAS-SOBRIA ENCODING AEROLYSIN AND ITS REGULATORY REGION
    HUSSLEIN, V
    HUHLE, B
    JARCHAU, T
    LURZ, R
    GOEBEL, W
    CHAKRABORTY, T
    [J]. MOLECULAR MICROBIOLOGY, 1988, 2 (04) : 507 - 517