Femoral Head Lag Screw Position for Cephalomedullary Nails: A Biomechanical Analysis

被引:158
作者
Kuzyk, Paul R. T. [1 ]
Zdero, Rad [2 ,3 ]
Shah, Suraj [2 ,3 ]
Olsen, Michael [2 ]
Waddell, James P. [1 ]
Schemitsch, Emil H. [1 ,2 ]
机构
[1] Univ Toronto, Dept Surg, Div Orthopaed, Toronto, ON, Canada
[2] St Michaels Hosp, Martin Orthopaed Biomech Lab, Toronto, ON M5B 1W8, Canada
[3] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON, Canada
关键词
lag screw; peritrochanteric fracture; cephalomedullary nail; biomechanical; FINITE-ELEMENT-ANALYSIS; SLIDING HIP SCREW; INTERTROCHANTERIC FRACTURES; TROCHANTERIC FRACTURES; INTRAMEDULLARY NAIL; SYNTHETIC FEMURS; CANCELLOUS BONE; GAMMA-NAIL; FIXATION; FAILURE;
D O I
10.1097/BOT.0b013e318229acca
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Objectives: The purpose of this study was to determine if lag screw position affects the biomechanical properties of a cephalomedullary nail used to fix an unstable peritrochanteric fracture. Methods: Unstable peritrochanteric fractures were created in 30 synthetic femurs and repaired with Long Gamma 3 Nails using one of 5 lag screw positions: superior, inferior, anterior, posterior, or central. Radiographic measurements including tip-apex distance and a calcar referenced tip-apex distance were calculated from anteroposterior and lateral radiographs. Specimens were tested for axial, lateral bending, and torsional stiffness and then loaded to failure in the axial position. Analysis of variance and linear regression were used for statistical analysis. Results: The inferior lag screw position had significantly greater mean axial stiffness than superior (P < 0.01), anterior (P = 0.02), and posterior (P = 0.04) positions. Analysis revealed significantly less mean torsional stiffness for the superior lag screw position compared with other lag screw positions (P < 0.01 all 4 pairings). No statistical differences were noted for lateral bending stiffness. Superior and central lag screw positions had significantly greater mean load-to-failure than anterior (P < 0.01 and P = 0.02) and posterior (P < 0.01 and P = 0.05) positions. There were significant negative linear correlations between stiffness with distance from the calcar on anteroposterior radiographs and load-to-failure with distance from the center of femoral neck on the lateral radiographs. Conclusions: The inferior lag screw position produced the highest axial and torsional stiffness. Anterior and posterior lag screw positions produced the lowest stiffnesses and load-to-failure. Inferior placement of the lag screw on the anteroposterior radiograph and central placement on the lateral radiographs is recommended.
引用
收藏
页码:414 / 421
页数:8
相关论文
共 31 条
[1]
Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur [J].
Adams, CI ;
Robinson, CM ;
Court-Brown, CM ;
McQueen, MM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (06) :394-400
[2]
Nail or plate fixation of intertrochanteric hip fractures: Changing pattern of practice [J].
Anglen, Jeffrey O. ;
Weinstein, James N. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (04) :700-707
[3]
THE VALUE OF THE TIP-APEX DISTANCE IN PREDICTING FAILURE OF FIXATION OF PERITROCHANTERIC FRACTURES OF THE HIP [J].
BAUMGAERTNER, MR ;
CURTIN, SL ;
LINDSKOG, DM ;
KEGGI, JM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (07) :1058-1064
[4]
Gamma Nails Revisited: Gamma Nails Versus Compression Hip Screws in the Management of Intertrochanteric Fractures of the Hip: A Meta-Analysis [J].
Bhandari, Mohit ;
Schemitsch, Emil ;
Joensson, Anders ;
Zlowodzki, Michael ;
Haidukewych, George J. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (06) :460-464
[5]
Regional differences in mechanical and material properties of femoral head cancellous bone in health and osteoarthritis [J].
Brown, SJ ;
Pollintine, P ;
Powell, DE ;
Davie, MWJ ;
Sharp, CA .
CALCIFIED TISSUE INTERNATIONAL, 2002, 71 (03) :227-234
[6]
Finite element analysis of a femoral retrograde intramedullary nail subject to gait loading [J].
Cheung, G ;
Zalzal, P ;
Bhandari, M ;
Spelt, JK ;
Papini, M .
MEDICAL ENGINEERING & PHYSICS, 2004, 26 (02) :93-108
[7]
The trochanteric nail versus the sliding hip screw for intertrochanteric hip fractures: A review of 93 cases [J].
Crawford, CH ;
Malkani, AL ;
Cordray, S ;
Roberts, CS ;
Sligar, W .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (02) :325-328
[8]
Mechanical validation of whole bone composite femur models [J].
Cristofolini, L ;
Viceconti, M ;
Cappello, A ;
Toni, A .
JOURNAL OF BIOMECHANICS, 1996, 29 (04) :525-535
[9]
Haidukewych GJ, 2009, J BONE JOINT SURG AM, V91A, P712
[10]
Failure of femoral head fixation: a cadaveric analysis of lag screw cut-out with the gamma locking nail and AO dynamic hip screw [J].
Haynes, RC ;
Poll, RG ;
Miles, AW ;
Weston, RB .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1997, 28 (5-6) :337-341